Cable Strength 

There shall be no sign of malfunction after the following cable strength test. 

Cable Strength Test:

 Affix the scanner to an immovable object and pull it using a force of 24.5 N 

(2.5 kgf static loading) for 1 second. Repeat this 20 times continuously. 

 
 

9.6.

 

Cable Bending Strength 

There shall be no sign of malfunction after the following cable bending test. 

Cable Bending Test: 

Add a load of 4.9 N (500 gf) to a cable and bend it at an angle of 60° to both 

right and left. Repeat this 1000 times continuously. 

 

 

 

Figure 21: Cable Bending 

 

 
 

9.7.

 

Vibration Strength (without packing) 

There shall be no sign of malfunction after the following vibration test.

  

Vibration test:

 Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated velocity 

of 19.6m/s

2

 (2.0 G) for 30 minutes (60 minutes per cycle) in the non-operating state. Repeat this in 

each X, Y and Z direction.  

 
 

9.8.

 

Vibration Strength (in individual packing) 

There shall be no sign of malfunction after the following vibration test. 

Vibration test: 

Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated velocity 

of 19.6 m/s

2

 (2.0 G) for 30 minutes (60 minutes per cycle) in individually packaged state. Repeat this 

in each X, Y and Z direction.  

 

 

Summary of Contents for NLV-3101-HD

Page 1: ...Fixed Position 2D Imager Scanner NLV 3101 HD This manual provides specifications for the NLV 3101 HD fixed position 2D imager scanner Specifications Manual HD High Density type ...

Page 2: ...defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental damages arisin...

Page 3: ...ns throughout Added US measurements to barcode resolutions where found throughout Convert term Loose End to Flying Lead where mentioned in reference to a no connector interface throughout Clarified unit of measure in graphics throughout 4 3 Added USA part number for power supply and updated accessory list to include universal plug adapters for power supply 40 8 1 Added USA Order number for power s...

Page 4: ...3 USB Interface Circuit 12 6 2 4 USB Interface Cable 13 6 3 Wedge PS 2 13 6 3 1 How to Connect 13 6 3 2 Caution 13 6 3 3 Pin Assignment 14 6 3 4 Wedge PS 2 Interface Cable 15 6 3 5 Wedge PS 2 Branch Cable 15 7 Optical Specifications 16 7 1 Basic Optical Specifications 16 7 2 Aiming Pattern 17 7 3 Imaging Range 17 8 Technical Specifications 18 8 1 Barcode Test Sample 19 8 2 Scan Area and Depth of F...

Page 5: ...ck 30 13 2 Temperature Conditions 30 13 3 Foreign Materials 30 13 4 Other 30 14 Product Label 31 15 Packaging Specifications 32 15 1 Individual Packaging 32 15 1 1 Included AC Adapter 32 15 1 2 Non Included AC Adapter 33 15 2 Collective Packaging 34 16 Physical Features 35 16 1 Dimensions 35 16 2 Weight 35 16 3 Mechanical Drawing 35 17 Default Setting 36 17 1 Default Setting Menu Code 36 17 2 Supp...

Page 6: ...light conditions Editing function A new function Data Editing Program captures up to 16 codes on multiple images simultaneously in one go Output editing process such as GS1 format also can be set easily World s most compact 2D scanner in its class The NLV 3101 offers ultra compact size and easy operation LED aiming A sharp single line of green LED makes it easy to aim the scanner while providing s...

Page 7: ...W 7 Industrial 2 of 5 Interleaved 2 of 5 S Code IATA Code 93 Code 128 MSI Plessey UK Plessey TELEPEN Matrix 2 of 5 Chinese Post Matrix 2 of 5 Code 11 Korean Postal Authority code Postal Code Minimum resolution Code 39 3 mils 0 076 mm PCS 0 9 Curvature Radius 20 mm 12 digit UPC PCS 0 9 Wide Bar Code Possible to read Code 39 with 70 mm width and resolution 0 2mm DOF 95 mm Motion tolerance Possible t...

Page 8: ...eft right column Resolution of output image Full 1 2 1 4 Interface of output image RS 232C USB COM Baud rate USB COM full speed About 3 sec Resolution Full RS 232C baud rate 15 2 kbps About 40 sec Power Range of operating voltage 4 5 5 5 V USB RS 232C flying lead 5 4 6 6 V RS 232C D Sub9pin Wedge external power supply RS 232C D Sub9pin Wedge External power supply Dedicated AC adapter 6 0 V 5 Curre...

Page 9: ...t Level 3 V m AM 80 AM Fast transient Voltage Alternating current input cable 1 kV Condition IEC61000 4 4 compliant Pulse 5 50 ns Tr Tw Frequency 5 kHz Surge Pulse 1 2 50 ns Tr Th Condition IEC61000 4 5 compliant Voltage From L to P 2 kV closed loop voltage From L to L 1 kV closed loop voltage Radio frequency common mode Frequency 0 15 80 MHz Condition IEC61000 4 6 compliant Level 3 V AM 80 AM Pow...

Page 10: ...NLV 3101 HD Specifications Manual 5 ...

Page 11: ...to dust and dirt before scanning 3 Status LED The operating statuses are indicated by different colors 4 Beeper Hole A sound from a built in beeper comes out through this hole When they are covered the beeper sound may not be able to be heard The sound varies depending on the status Beeper settings can be configured in various ways enable or disable beeper as well as change the loudness and durati...

Page 12: ... voltage 4 5 5 5 V Power ripple 100 mVp p max 10 100 kHz power supply voltage 5 0 V Current consumption 250 mA max without main power supply AC adapter 5 mA max in standby state with main power supply AC adapter Current consumption from the main power supply in standby state 155 mA max Current consumption from the main power supply during reading operation 305 mA max Keyboard operation is possible...

Page 13: ...ansmitted via RS 232C interface Signal Level signal names are based on the signals transmitted from the scanner to the host Signal Name IN OUT Voltage V Mark Space TxD OUT 5 15 5 15 RxD IN 3 15 3 15 RTS OUT 5 15 5 15 CTS IN 3 15 3 15 Signal Level sequencer signals flying lead spec only Signal Name IN OUT Voltage V L level Space ON External trigger IN 0 3 0 6 V 3 V Vcc 0 3 V OK OUT 0 3 V 10 mA OC o...

Page 14: ...2 RS 232C D Sub 9pin Circuit Figure 3 RS 232C D Sub 9pin Circuit Connector D Sub 9pin female Power supply EIAJ RC5320A voltage classification 2 jack 6 1 1 3 RS 232C D Sub 9pin Interface Cable Weight approx 90 g Figure 4 Cable RS 232C D Sub 9pin ...

Page 15: ...4 5 5 5 V Typ 5 V Trigger Brown External trigger input terminal OK Yellow External OK output terminal NG Orange External NG output terminal S GND Black RTS Gray CTS Blue TxD Green RxD White Shield GND Black Heat shrinkable tube Be sure the wiring is done correctly 6 1 2 2 RS 232C Flying Lead Circuit Figure 5 RS 232C Flying Lead Circuit ...

Page 16: ...NLV 3101 HD Specifications Manual 11 6 1 2 3 RS 232C Flying Lead Interface Cable Weight approx 45 g unit mm Figure 6 Cable RS 232C Flying Lead ...

Page 17: ...smitted via USB COM interface 6 2 1 USB Interface Specifications Power supply 500mA High Power Speed Full speed 12 Mbps Interface USB HID USB COM VCP The USB model is bus powered and no AC adapter is required Images cannot be transmitted via the USB HID interface Multi byte character data can be transmitted via USB HID interface with settings Make sure to connect to a High power bus 500 mA max USB...

Page 18: ...6 pin Mini DIN female to the keyboard Insert the AC adapter plug to the DC jack of the interface cable and start the host computer 6 3 2 Caution Do not operate on the keyboard during the data transmission to the host or the data transmission may fail The keyboard can operate without connecting to the AC adapter when this device is not used However do not turn ON or OFF the adapter while operating ...

Page 19: ...e Pin No Signal Name 1 KEY DATA 2 N C 3 GND 4 VCC 5 KEY CLK 6 N C Pin No Signal Name 1 CPU DATA 2 N C 3 GND 4 VCC 5 CPU CLK 6 N C Wedge PS 2 Interface Cable for the NLV 3101 Pin No Signal Name 1 CPU DATA 2 KEY DATA 3 GND 4 VCC 5 CPU CLK 6 KEY CKL Figure 10 Pin Assignment Wedge PS 2 ...

Page 20: ...PS 2 Interface Cable Weight approx 75 g unit mm Figure 11 Cable Wedge PS 2 6 3 5 Wedge PS 2 Branch Cable Weight approx 25 g This cable is required when connecting both the scanner and the keyboard to the host unit mm Figure 12 Branch Cable Wedge PS 2 ...

Page 21: ...e Distance from the front edge of scanner 65 mm View angle Horizontal Approx 40 6 Vertical Approx 26 4 Illumination light source LED 2 Red LED Peak wavelength 617 nm Directivity angle 2Φ 1 2 2 60 Maximum radiation output 3 15000 mcd Aiming light source Green LED Peak wavelength 528 nm Maximum radiation output 4 18700 mcd 1 The fastest seed of image capture 2 Reference value extracted from the data...

Page 22: ...h coincide at a distance of L 105 20 mm from the front edge of the scanner The horizontal aiming width to the horizontal width of imaging filed of view at a distance of L 105 is 80 10 Figure 13 Aiming Pattern and Imaging Range 7 3 Imaging Range The range is 5 from the following values L Distance from the front edge of scanner mm 40 50 65 80 100 120 H Horizontal imaging range mm 30 37 48 59 74 89 V...

Page 23: ... Ambient Temperature and Humidity Room temperature room humidity Ambient Light 100 200 lux on the surface of a bar code Angles Pitch α 0 Skew β 15 Tilt γ 0 Curvature R Power Supply Voltage 5 0 V PCS 1D and 2D 0 9 or higher Scanning Test Accept the performance with 90 or more success rate for 10 tries of scan One scan should be tested within 1 second Barcode Test Sample 1D and 2D Specified below Te...

Page 24: ... 31 5 25 0 12 GS1 Databar Composite GS1 limited Resolution Symbology PCS Size mm No of Digits 5 mils 0 127 mm Limited 0 9 9 0 1 0 14 5 mils 0 127 mm Limited Composite 0 9 9 0 2 5 26 2D Codes PDF417 Resolution Error Correction PCS Size mm No of Character 5 mils 0 127 mm Level 3 0 9 12 8 58 10 mils 0 254 mm 35 15 QR Code Model 2 Resolution Error Correction PCS Size mm No of Character 5 mils 0 127 mm...

Page 25: ...ing position by placing a label near the middle of depth of field and eliminate ambient light and specular light from LED illumination Figure 14 Scan Area and Depth of Field 55 100 125 80 65 110 65 45 110 70 80 65 90 Code 128 UPC 100 PDF417 QR Code Data Matrix 0 18 7 1mil 0 33 13mil 0 127 5mil 0 254 10mil 0 212 8 4mil 0 381 15mil 0 169 6 7mil 60 65 85 110 Code 39 0 127 5mil 0 254 10mil Unit mm 60 ...

Page 26: ...ode 39 specified in Chapter 8 1 GS1 Databar 5 mils 0 127 mm GS1 Databar Limited specified in Chapter 8 1 Stacked Code 5 mils 0 127 mm PDF417 GS1 Databar Limited Composite specified in Chapter 8 1 2D Code 5 mils 0 127 mm QR Code and Data Matrix specified in Chapter 8 1 Conditions Bar Code Sample The above codes specified in Chapter 8 1 Distance 65 mm from the front edge of the scanner Angle α 0 β 1...

Page 27: ...r the pitch angle and tilt angle measurement set the skew angle β 15 Figure 16 Pitch Skew and Tilt 8 7 Curvature 0 33 mm 12 digit UPC R 20 mm Conditions Bar Code Sample 0 33 mm UPC 0 15 mm Codabar specified in Chapter 8 1 Distance 65 mm from the front edge of the scanner Angle α 0 β 15 γ 0 Figure 17 Curvature Note Scanning may fail due to the specular reflection of LED illumination when the reflec...

Page 28: ...ver gray 010010016 Ambient Light 500 1000 lux Moving Speed of Detected Paper 2 m second or slower Ambient Temperature and Humidity Room temperature and room humidity Figure 18 Auto Trigger 8 9 Motion Tolerance 0 381mm QR Code can be read when it is moving at 1m s Conditions Ambient Temperature and Humidity Room temperature and Room humidity Ambient Light 500 1000 lux Distance 95 mm from the front ...

Page 29: ...NLV 3101 HD Specifications Manual 24 ...

Page 30: ...15 γ 0 Curvature R Scanning Test Read at intervals of 300 ms When you attach this scanner to a place with few crevices or the bad place of breathability please check the circumference temperature of this scanner 9 2 Humidity Scanning performance is guaranteed when the range of ambient humidity around the scanner is the following values Operating Humidity 20 85 RH no condensation no frost Storage H...

Page 31: ...ight 10 000 lux Sunlight 100 000 lux Conditions Bar Code Sample 0 33 mm UPC specified in Chapter 8 1 Distance 65 mm from the front edge of the camera module Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 3 3 and 5 0 V Figure 20 Ambient Light Immunity Be sure that the direct light or specular reflection from the light source does not enter the light receiving section of the NLV 3101 9 4 Dust a...

Page 32: ...1000 times continuously Figure 21 Cable Bending 9 7 Vibration Strength without packing There shall be no sign of malfunction after the following vibration test Vibration test Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated velocity of 19 6m s 2 2 0 G for 30 minutes 60 minutes per cycle in the non operating state Repeat this in each X Y and Z direction 9 8 Vibration Str...

Page 33: ...op test Drop test Drop an individually packaged scanner 10 times in total at any of 1 corner 3 edges and 6 faces from a height of 100 cm onto a concrete floor 9 11 Electrical Specifications Withstand Voltage AC 1500 V 60 seconds 10 mA or less Insulation Resistance DC 500 V 2 MΩ or higher Current Leakage 250 μA or less AC 250 V 60 Hz Power Line Noise Immunity 1 kV or lower Electrostatic Discharge I...

Page 34: ...471 2006 Exempt Risk Group 10 2 EMC EN55022 EN55024 FCC Part 15 Subpart B Class B VCCI Class B 11 RoHS The NLV 3101 is compliant with RoHS RoHS The restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC This is a Class B product to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference...

Page 35: ...Shock Do not throw or drop the imager Do not place heavy objects on the cables 13 2 Temperature Conditions Do not use the imager at temperatures outside the specified range Do not pour boiling water on the imager Do not throw the imager into the fire Do not forcibly bend the cables at low temperatures 13 3 Foreign Materials Do not subject the imager to chemicals 13 4 Other Do not plug unplug the c...

Page 36: ...NLV 3101 HD Specifications Manual 31 14 Product Label The product label is affixed to the scanner as shown below Figure 23 Product Label Position Figure 24 Enlarged View of Label Serial number ...

Page 37: ...NLV 3101 HD Specifications Manual 32 15 Packaging Specifications 15 1 Individual Packaging 15 1 1 Included AC Adapter Figure 25 Individual Packaging with AC adapter RS 232C D Sub 9pin example ...

Page 38: ...NLV 3101 HD Specifications Manual 33 15 1 2 Non Included AC Adapter Figure 26 Individual Packaging without AC adapter USB HID example g ...

Page 39: ...0 x 525 x 290 WDH mm 50 units without AC adapter package size 600 x 525 x 250 WDH mm Figure 27 Collective Packaging with AC adapter RS 232C D Sub 9pin example Note ʻRo markʼ on the trays and the boxes for the product indicates that the product is RoHS compliant which is declared by Optoelectronics Co Ltd ...

Page 40: ... 3101 HD Specifications Manual 35 16 Physical Features 16 1 Dimensions Approx 33 0 41 1 24 0 WDH mm 16 2 Weight Approx 30 g excluding the cable 16 3 Mechanical Drawing unit mm Figure 28 Mechanical Drawing ...

Page 41: ... length Remarks UPC UPC Add on 2 UPC Add on 5 EAN JAN EAN Add on 2 EAN Add on 5 EAN 13 EAN 13 Add on 2 EAN 13 Add on 5 EAN 8 EAN 8 Add on 2 EAN 8 Add on 5 Code 39 1 Not transmit ST SP Tri Optic Not transmit ST SP Codabar NW7 1 Not transmit ST SP Industrial 2of 5 5 Interleaved 2of 5 6 S Code 5 Code 128 1 GS1 conversion setting required Code 93 1 IATA 5 MSI Plessey 3 UK Plessey 2 Telepen 1 Code 11 1...

Page 42: ... CC A Limited CC B Expanded CC A Expanded CC B GS1 conversion setting required Composite GS1 128 CC A CC B CC C GS1 conversion setting required Composite EAN EAN 13 CC A EAN 13 CC B EAN 8 CC A EAN 8 CC B GS1 conversion setting required Composite UPC UPC A CC A UPC A CC B UPC E CC A UPC E CC B GS1 conversion setting required 17 2 3 2D Codes Code type Default Remarks PDF417 Micro PDF417 Codablock F ...

Page 43: ...is recommended to use buffered mode for USB HID and Wedge PS 2 interfaces and unbuffered mode for RS 232C and USB COM interfaces Unbuffered mode Buffered mode default M E N U O P T O ZZ D 80 ZZ O T P O U N E M M E N U O P T O ZZ D 81 ZZ O T P O U N E M Refer to NLV 3101 Userʼs Manual for supported commands 17 4 RS 232C Default Item Default Setting Baud rate 9600 bps Parity bits No parity Data leng...

Page 44: ... Item Description Baud rate USB2 0 Full Speed Power supply 500 mA Vender ID 065A Product ID A002 Supported OS Microsoft Windows 2000 XP Vista 7 32 64 bit Standards CDC ACM 17 6 USB HID Wedge Defaults Item Default Setting Keyboard language USA Output mode Output all values Character encoding None LF output Disable ...

Page 45: ... the detailed view Item Specifications Model Name SFP0602000P PSE Order Part No USA 32 00606 00 Dimensions 47 5 x 28 0 x 75 0 WDH mm DC Output Cable Length 1 8 m Input Spec Voltage Range AC 90 265 V Supply Current 0 5 A max Output Spec Voltage Range 5 7 6 3 V Maximum Current 2 A max Operating Temperature 0 40 C 18 2 AC Adapter Mechanical Drawing Figure 29 AC Adapter input side The polarity of the ...

Reviews: