NLV
-
3101
-
HD
Specifications Manual
38
17.3.
Other Default
Item
Default Setting
Read mode
Single read
Extended read time
Disable
Beeper duration
100 ms
Beeper tone
2.7 kHz
Startup beeper
Enable
Beeper loudness
Max (100%)
Beeper timing
Before data transmission
Good read LED indicator duration
200 ms
Data buffering
Buffered mode
[Data buffering]
Not all output data can be received depending on the host system. Therefore, it is recommended to
use buffered mode for USB-HID and Wedge PS/2 interfaces and unbuffered mode for RS-232C and
USB-COM interfaces.
Unbuffered mode
Buffered mode (default)
@ M E N U̲ O P T O @ Z Z @ D 80 @ Z Z @ O T P O ̲U N E M @
@ M E N U̲ O P T O @ Z Z @ D 81 @ Z Z @ O T P O ̲U N E M @
* Refer to “NLV-3101 User
ʼ
s Manual” for supported commands.
17.4.
RS-232C Default
Item
Default Setting
Baud rate
9600 bps
Parity bits
No parity
Data length
8 bits
Stop bits
1 bit
Handshaking
No handshake
ACK/NAK
ACK/NAK no response
CTS time out
Indefinitely
ACK/NAK time out
1 second
Command header
ESC or STX
Command terminator
CR or ETX
Response to the commands
Disable