PX-36
V-1.0
19
7.4.7 Pitch, Skew and Tilt
Pitch
α = ±50°
Skew
β = ±50°
Tilt
γ = ±180°
<Conditions>
Bar code
UPC (resolution 0.33 mm) specified in Chapter 7.4.2
Distance
105 mm from the front edge of the scanner
Curvature
R = ∞
Angle
Pitch
β = +15°, γ = 0°
Skew, Dead zone
α = 0°, γ = 0°
Tilt
α = 0°, β = +15°
Figure 7: Pitch, Skew and Tilt
7.4.8 Curvature
0.33 mm 12-digit UPC
R
≥ 20 mm
0.15 mm 10-digit Codabar (NW-7)
R
≥ 16 mm
<Conditions>
Bar code
UPC (0.33 mm) and Codabar (0.15 mm) specified in Section 8.1.
Distance
85 mm from the front edge of the scanner
Angle
α = 0°, β = +15°, γ = 0°
Figure 8: Curvature
* The reading characteristics may deteriorate due to specular reflection of the LED illumination when reflectivity is
high.