5.2  To think about when and after using the 

microscope 

-  The microscope should always be kept vertically when moving it and be 

careful so that no moving parts, such as the eyepieces, fall out. 

-  Never mishandle or impose unnecessary force on the microscope. 

-  Never attempt to service the microscope yourself. 

-  After use, turn off the light immediately, cover the microscope with the 

included dust-cover, and keep it in a dry and clean place.  

5.3  Electrical safety precautions 

-  Before plugging in the power supply, make sure that the supplying voltage of 

your region matches with the operation voltage of the equipment and that 
the lamp switch is in off-position. 

-  Users should observe all safety regulations of the region. The equipment 

has acquired the CE safety label. However, users do have full responsibility 
to use this equipment safely. 

5.4  Cleaning the optics 

-  If the optical parts need to be cleaned try first to: use compressed air. 

-  If that is not sufficient: use a soft lint-free piece of cloth with water and a 

mild detergent. 

-  And as a final option: use the piece of cloth moistened with a 3:7 mixture of 

ethanol and ether.  

Note:

 ethanol and ether are highly flammable liquids. Do not use them near a 

heat source, near sparks or near electric equipment. Use these chemicals in a 
well ventilated room. 

-  Remember to never wipe the surface of any optical items with your hands. 

Fingerprints can damage the optics. 

-  Do not disassemble objectives or eyepieces in attempt to clean them. 

5.5  Instructions to return your product to the supplier 

If you need to send the microscope to Jeulin for maintenance, please use the 
original packaging. 

6 Technical 

specifications 

HEAD: B-191:

 

monocular, 360° rotating, 30° inclined  

 

B-192:

 

binocular, rotating, inclined  

EYEPIECES:

 

WF 10X/ 18mm  

NOSEPIECE:

 

Quadruple, reversed  

OBJECTIVES:

 

Achromatic 4x, 10x, 40x, 100x (oil immersion) 

WORKING STAGE

Double layer with mechanical sliding stage, 
125x115mm, moving range 50x30mm  

CONDENSER:

 

1.25N.A. Abbe type, with iris diaphragm  

FOCUSING SYSTEM:

  Coaxial coarse and fine focusing system, with tension 

adjustment mechanism  

ILLUMINATION:

 

Extra-power White LED, non-rechargeable, with 
brightness control. 

MAINS POWER:

 

Input Voltage of the power supply: 100-240Vac / 50-
60Hz  

Summary of Contents for B-190

Page 1: ...Observation Microscopie Observation Microscopy R f 571 248 571 249 Fran ais p 1 English p 9 Version 0104 Microscopes OPTIKA s rie B 190 Microscopes OPTIKA B 190 series...

Page 2: ...f 571 248 571 249 FRAN AIS 1 Sommaire 1 Description 2 2 Introduction 4 3 D ballage montage et branchement 4 4 Utilisation du microscope 4 5 Entretien 6 6 Caract ristiques techniques 7 7 Mesures colog...

Page 3: ...ion des pr parations Commande de mise au point macrom trique Commande de mise au point microm trique R glage de l intensit lumineuse clairage LED Mise au point coaxiale Commandes coaxiales de mouvemen...

Page 4: ...Microscopie Microscopes OPTIKA R f 571 248 571 249 FRAN AIS 3 Vue arri re T te monoculaire B 191 Commande de r glage de la tension Douille d alimentation Interrupteur ON OFF...

Page 5: ...ne pas endommager les composants optiques objectifs et oculaires et vitez que l appareil ne tombe Soulevez le microscope avec les deux mains une main pour soutenir le bras du microscope et de l autre...

Page 6: ...jusqu obtenir une image claire et d finie en utilisant le plus petit grossissement de l objectif Observez avec l oeil droit tournez l anneau de compensation dioptrique situ sur l oculaire de gauche j...

Page 7: ...riv e de l endroit o sera connect l appareil correspond la tension appropri e pour l utilisation du microscope et que l interrupteur soit bien en position OFF L utilisateur doit consulter les normes d...

Page 8: ...nsion l entr e de l alimentation 100 240 Vac 50 60 Hz 7 Mesures cologiques Ce symbole indique que l appareil peut tre source de mati res premi res importantes et que par cons quent il ne doit pas tre...

Page 9: ...vente La garantie est de 2 ans le mat riel doit tre retourn dans nos ateliers Pour toutes r parations r glages ou pi ces d tach es veuillez contacter JEULIN SUPPORT TECHNIQUE Rue Jacques Monod BP 190...

Page 10: ...R f 571 248 571 249 ENGLISH 9 Contents 1 Description 10 2 Introduction 12 3 Unpacking and assembly 12 4 Using the microscope 12 5 Maintenance 13 6 Technical specifications 14 7 Recovery and recycling...

Page 11: ...scription Binocular observation head B 192 Eyepiece Objective Slide clamp Coarse focusing knob Fine focusing knob Brightness adjustment knob LED illuminator Tension adjustment knob Translation knobs C...

Page 12: ...Microscopy Microscopes OPTIKA R f 571 248 571 249 ENGLISH 11 Rear Monocular observation head B 191 Tension adjustment knob Power supply input jack ON OFF switch...

Page 13: ...d one around the base lift the microscope from the container and put it on a stable desk 3 2 Assembly Place the observation head onto the top of the arm and tighten the lock screw Insert the eyepieces...

Page 14: ...Turn the tension adjust knob to get a suitable tension for the focus system When the image is in focus turn the nosepiece to choose the objective you need 4 6 Condenser adjustment Hold the notched rin...

Page 15: ...ree piece of cloth with water and a mild detergent And as a final option use the piece of cloth moistened with a 3 7 mixture of ethanol and ether Note ethanol and ether are highly flammable liquids Do...

Page 16: ...elp When at the end of its operating life you shall decide to dispose of the apparatus do not try to open it nor to use parts of it in ways other than reported in this Manual but bring it back to the...

Page 17: ......

Reviews: