P/N OPT-7790
WARNING
If the information in these instructions is not followed exactly, an electrical
hazard may result, causing property damage, personal injury or death
A: Sensor Installation
IMPORTANT:
Turn off all power at the circuit breakers. If the equipment is below
the pool, turn off any valves to prevent pool water from draining.
For water temperature sensor:
1
Loosen the clamp and remove the old Water Temperature Sensor. (For a new
installation Drill a 3/8” hole in the pipe between the filter pump and the filter.).
2
Ensure the o-ring on the sensor and insert the sensor into the pipe.
3
Tighten the pipe clamp around the sensor. Be sure the wire is not under the pipe clamp
or pinched.
For air temperature sensor:
1
Install the Air Temperature Sensor in a convenient location exposed to shaded outdoor
air temperatures.
2
DO NOT place the sensor in direct sunlight.
For solar temperature sensor:
1
Install the Solar Temperature Sensor next to the solar panels.
2
DO NOT place the sensor in the pipe or in direct sunlight.
B: Sensor Wiring
1
Run the sensor wire to the AquaLink RS Power Center.
Be sure to run the wire in the
low voltage raceway (See wiring diagram on Power Center door).
2
Remove the green 10-pin terminal bar from the Power Center Board.
3
Connect the temperature sensor wires to the green 10-pin terminal bar in the positions
indicated on the wiring diagram located on the door of the Power Center.
4
Replace the green 10-pin terminal bar on the Power Center Board.
5
Restore power to the system and check for normal system operation.
IMPORTANT
: Determine the length the sensor wire needs to be. Cut the end of the wire off,
DO NOT splice this wire.