background image

P/N OPT-7790 

WARNING 

If the information in these instructions is not followed exactly, an electrical 

hazard may result, causing property damage, personal injury or death 

 
A:  Sensor Installation 

IMPORTANT: 

Turn off all power at the circuit breakers. If the equipment is below 

the pool, turn off any valves to prevent pool water from draining. 

 
For water temperature sensor: 

1

 

Loosen the clamp and remove the old Water Temperature Sensor.  (For a new 

installation Drill a 3/8” hole in the pipe between the filter pump and the filter.).

 

2

 

Ensure the o-ring on the sensor and insert the sensor into the pipe. 

3

 

Tighten the pipe clamp around the sensor. Be sure the wire is not under the pipe clamp 
or pinched. 
 

For air temperature sensor: 

1

 

Install the Air Temperature Sensor in a convenient location exposed to shaded outdoor 
air temperatures. 

2

 

DO NOT place the sensor in direct sunlight. 

 
For solar temperature sensor: 

1

 

Install the Solar Temperature Sensor next to the solar panels.  

2

 

DO NOT place the sensor in the pipe or in direct sunlight. 

 

B: Sensor Wiring 

1

 

Run the sensor wire to the AquaLink RS Power Center. 

Be sure to run the wire in the 

low voltage raceway (See wiring diagram on Power Center door). 

2

 

Remove the green 10-pin terminal bar from the Power Center Board. 

3

 

Connect the temperature sensor wires to the green 10-pin terminal bar in the positions 
indicated on the wiring diagram located on the door of the Power Center. 

4

 

Replace the green 10-pin terminal bar on the Power Center Board. 

5

 

Restore power to the system and check for normal system operation. 
 

 

IMPORTANT

: Determine the length the sensor wire needs to be. Cut the end of the wire off, 

DO NOT splice this wire. 