A-065M Version 1.0
Page
7
of 13
A-065M
Amplifier
4. FUNCTIONALITY
4.1. Input
gain
control
Channels 1 to 3 have a gain control which permits to adjust, in a 44 dB range, the sensitivity of
each one.
4.2. CH1 Priority and TEL-PAGING
This equipment includes VOX priority for TEL-PAGING input over all channels and for channel 1
input over channels 2 and 3. When priority is activated, lower priority channels are muted.
In order to activate the priority of channel 1, TALKOVER switch must be set to ON position.
TEL-PAGING activation threshold can be adjusted by TALKOVER control.
This equipment has two priority layers:
1
Æ
TEL-PAGING.
2
Æ
CH1 (With priority activated)
2
Æ
CH1 (Without priority activated), CH2 y CH3.
4.3. Phantom
power
This equipment has Phantom power +15 Vdc selectable for Channel 1.