Proceed as follows:
1. Click on the button Add.
2. Select an amplifier from the drop-down menu.
2. Select the type of message.
3. Select the message number.
4. Select the priority level of the message with respect to the other
signals that the amplifier has to reproduce.
It is possible to add to or modify this configuration by selecting an
element from the list and using the buttons
Modify (7)
or
Delete (8)
.
The diagram attached
provides an example with
the configuration described
on the previous page.
Activation of contact 2 of
the amplifier in Zone 2
leads to:
Playback of message 1
with priority 1 in Zone 2
Playback of message 2
with priority 3 in Zone 1
Playback of message 1
with priority 2 in Zone 3
3. Input contact: Local Message Reset
Activation of the contact stops the playback of a local
pre-recorded message from the amplifier.
(1) Name
. Enter a name to identify the contact.
(2) Contact Status
. Defines the standby status of
the contact (NO: Contact normally open; NC: Contact
normally closed). Variation in this status will stop the
message that is being played.
(3) Message Type
. Select the memory in which the
message that you wish to stop is located.
(4) Message
. Number of the message that will be
stopped when the contact is activated.
(1)
(2)
(3)