(3)
(1)
(2)
(4)
(3)
(1)
(2)
(4)
4. Output contact: Associated Input
The output contact is activated when an input contact is activated.
(1) Name
. Enter a name to identify the contact.
(2) Contact status
. Defines the standby status of the contact
(NO: Contact normally open; NC: Contact
normally closed).
(3) Associated input
contact
. Input
contacts whose
activation activates the
output contact. Click
on the button
Config
(4)
and select the
input contacts
required. To make a
multiple selection, hold
the
Ctrl.
key down.
5. Output contact: Associated Group
This functionality activates the output contact when the message is sent to a group. It is used for the
creation of “subzones” (activation of MC-L line switching modules).
(1) Name
. Enter a name to identify the contact.
(2) Contact Status
. Defines the standby status of the contact
(NO: Contact normally open; NC: Contact normally closed).
(3) Associated
Group
. Groups whose
activation will lead to
the activation of the
output contact.
The zone
corresponding to the
amplifier whose
contact is being
configured must form
part of the group.
Click on the button
Config (4)
and select
the groups required.
To make a multiple
selection, hold the
Ctrl.
key down.