Appendix A – Specifications 

 
 

 

 
 
 

 

 

Ozone Generator 
Power Supply 

Ozone Outlet 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Air Compressor 

 

 

Power Cord 

Control Board 

Ozone Cell 

Fan 

Summary of Contents for Sanit-ICE

Page 1: ...OptiPure a Division of Aquion Inc Commercial Water Filtration Systems 101 S Gary Ave Suite A Roselle IL 60172 972 881 9797 E mail info optipure net www optipurewater com Copyright 2018 OptiPure Repro...

Page 2: ......

Page 3: ...or maintenance procedure associated with this equipment Failure to follow these instructions could result in personal injury damage to the equipment or reduced product performance In an ongoing effor...

Page 4: ...tions 4 Installation Procedures 6 Figure 1 Feature Callout 7 Figure 2 Typical Installation 7 Operating Instructions 8 Figure 3 Summary of LED Indicators 8 Trouble Shooting 9 Servicing 9 Appendix A Spe...

Page 5: ...gen leaving no harsh chemical residue and discharging no harsh chemicals into the water No chemicals mean the taste of the water and subsequent ice produced is not negatively impacted This unit will a...

Page 6: ...using harsh chemicals abrasives or cleaners 7 Warning The unit has only been evaluated for mechanical electric shock and fire hazards The method to control ozone release or the effectiveness of the w...

Page 7: ...stalled and grounded in accordance with all local codes and ordinances 12 WARNING Improper connection of the appliance grounding conductor can result in a risk of electric shock Check with a qualified...

Page 8: ...l surface Please consider the following when selecting a mounting location Never install the Sanit ICE System in an area where water may freeze Freezing water will damage the internal components The S...

Page 9: ...in ice maker Attach the opposite end of the tubing to the barbed fitting of the diffuser provided and place the diffuser into the water reservoir Plug the Sanit ICE System into a GFCI protected outle...

Page 10: ...roduced at the beginning of a cycle for a time period based on your profile and the unit must reach a new cycle before ozone is produced again In the event of power loss the Sanit ICE System will reme...

Page 11: ...ing any maintenance procedures As Needed Clean fan filter Remove fan cover by grasping the fan grill witha pair of needle nose pliers and gently pulling Take out foam filter wash filter with warm soap...

Page 12: ...mm Outlet 3 16 Barb Power 120 240 VAC 50 60 Hz Power Connection 6 1 8m 3 prong cord Mounting Z bar Ambient Conditions 32 95 F 0 35 C 10 90 RH non condensing Shipping Weight 3 5 lbs 1 6 kg Performance...

Page 13: ...11 Appendix A Specifications Ozone Generator Power Supply Ozone Outlet Air Compressor Power Cord Control Board Ozone Cell Fan...

Page 14: ...t misuse alteration or abuse An act of God such as flood earthquake hurricane lightning or other disaster resulting only from the forces of nature Normal wear and tear Operation outside the usage para...

Page 15: ...any and all warranties For service contact your authorized dealer or distributor or OptiPure direct at 972 881 9797 Exclusive Warranty There is no other expressed warranty on OptiPure products and or...

Page 16: ......