5. Accessories 

A.

 5X lenses   

B. Power adapter 

 

 

6. Cleaning and maintenance

 

Keep the lens inspection station dry and clean. Please clean it with lens cleaner or soft cloth.   
Caution: please do not clean with alcohol or any corrosive cleanser to avoid damage of the surface. 
 

 

7. Trouble Shooting Guide 

1) Connect the power and turn on the machine. If the light is not on, it may be caused by the bad connection of 
the power socket. Rotate the power adapter connection port slightly to check if the machine could light up. 
 
2)When the machine uses the battery power, if the light of the lower inspection window flashes, it means the 
voltage is lower than 2.8V, please charge the batteries or use AC power. 
 

If it still can’t work, please contact the Repair department or an authorized distributor.

 

 

8. Specifications: 

1) 

Power: AC 100-240V 50-60Hz 0.4A 

2) Power Adapter: DC 5V-6.5V 3A (6.5V MAX) 

3) Dimension: 230*150*320mm 

4) Weight: 1.65kg 

5) Optional accessory

  18650 rechargeable battery(12580mWh) * 2 

 

 
 

Subject to change in design or specifications without advance notice 

Version  1.0 

- 8 -

 

 

If Lens stress has not been dealt with properly, the patient looks forward without any problem, but when he looks 
aside, he would feel uncomfortable and unclear view exists. This situation usually appears on the full or half frame 
eyeglasses, but not for the rimless ones. 
 
The stress of PC le

ns can’t be avoided. However, the imaging quality will be much better if the lens stress is 

small. 

 

 

5) Function III - Final Inspection 

Steps: 

A

. Put PAL/Inspection TOP lens on the upper window. The direction mark is aligned with U-shaped groove.   

 
B. Put Inspection BOTTOM lens on the lower window. The direction mark is aligned with U-shaped groove. 
 
C. Put the lens between the inspection lenses. Observe the surface of the lens. 
 
D. Scratching, bubbling and other coating problems can be checked out. 

 

4. Operation Indicator Light 

 

Operation Indicator Light Instructions 

The order of the 

indicator lights 

           Indictor                   

 

Status 

Operation 

Indicator 1 

Operation 

Indicator 2 

Operation 

Indicator 3 

Note 

At the battery chamber 
side, from left to right

 

5V DC power, without 

battery 

flash 

on 

on 

Without battery, 

indicator 1 flashes 

Operation Indicator 1

Charging(red) 

5V DC Power, with 

battery 

on 

off 

on 

The batteries are not 

fully charged 

Operation Indicator 2

Full(green) 

off 

on 

on 

The batteries are fully 

charged 

Battery Power 

off 

off 

on 

5V DC power is not 

connected 

Operation Indicator 3

Booster(green) 

 