Attentions

!!

 

1.  Purpose 

This series microscope is used only for microscopic observation , not available for other 
purpose, otherwise result in equipment damage. 
 

2.  Disassembly only by the professionals 

The  microscope  has  been  adjusted  before  shipping,  Unprofessional-person  should  not 
disassemble and remove any other parts. Disassemble and remove any other parts will 
result in equipment damage . 

 

If you have any questions, please contact with manufacturer or local distributor. 
 

3. 

Note the input voltage if 

correspond. 

This  instrument  designed  for  wide  input  voltage  (100V~240V,  50/60HZ),  applicable  to 
most area .But if the supply voltage exceeds this range, the instrument will be seriously 
damaged. 

4.  Prevent Burns And Fire 

When using power equipment, bulbs and collecting mirror and other nearby parts of the 
set  will  rise  sharply  in  temperature  until  it  reaches  a  thermal  equilibrium  state.  Pay 
attention to anti-hot logo, they should be careful not be burn when in use.   

Alcohol, gasoline, paper and other flammable materials can’t near the lamp in case 
of fire. 

 

5.  Notes On Replacing The Bulb. 

Replacement  should  be  based  on  the  identity  of  the  instrument  using  the  same 
specifications of the bulb, otherwise it may cause equipment damage.

 

The power supply must be cut off before bulb replacement, the bulb must be cooled off 
completely before proceeding! ! 
 

6.  Carry     

Power must be cut off before moving. Be careful not to crush your finger when placed.   
This instrument is a precision instrument, and it should be handle with care, severe shock 
can cause serious damage to equipment-related parts.   

7.  Installation   

Please refer to the installation instruction in order to avoid to damage the instrument . 

8.  Operation Environment 

The required available environment for using of the equipment: 
Indoor temperature: 0 

 ~ 40 

            maximum relative humidity: 85% 

High  temperature  or  high  humidity  may  cause  mildew,  fog  or  dew  of  the  optical 
components, and make the instrument not work. 

 
9.  Packing Waste Disposal

 

For  the  protection  of  the  environment,  please  properly  handle  the  microscope  packing 
waste or send to 

salvage station

(

such as: cardboard, foam, etc. )! 

 

Summary of Contents for A13.2604-A

Page 1: ...604 B Metallurgical Microscope Reflect Transmit Instruction Manual To ensure the safety and obtain satisfactory performance please study this instruction manual thoroughly be fore start to use the instrument ...

Page 2: ...in use Alcohol gasoline paper and other flammable materials can t near the lamp in case of fire 5 Notes On Replacing The Bulb Replacement should be based on the identity of the instrument using the same specifications of the bulb otherwise it may cause equipment damage The power supply must be cut off before bulb replacement the bulb must be cooled off completely before proceeding 6 Carry Power mu...

Page 3: ...57X C mount also provide digital camera for CCD SLR digital camera or special designing camera by our company It has many advantages for example fine appearance stable performance excellent image convenient usage etc Widely used in factories universities and relative research institutes This series microscope is suitable for observing various metallurgical specimens casting quality and identificat...

Page 4: ...topf trinocular head with output connector for CCD Camera SLR Digital Camera 1 6 Nosepiece Quintuple 1 7 Mechanical stage For Reflecting Illumination Size 200mm 150mm Travel range 77mm 52mm For Transmitting Illumination Size175mm 145mm Travel range 77mm 52mm Two slid holder 1 8 Focusing systems Coaxial Coarse and Fine Focusing Knobs Coarse stroke 22mm Fine division 2µm Condenser up down range 25mm...

Page 5: ...Plate Stage Halogen lamp house Lamp house fix screw Reflection illumination Aperture diaphragm lever Filter slider Field diaphragm lever Polarizing slider Main body Right fine focusing knob Right coarse focusing knob Ground glass slider Slider handle Eyepiece tube fix screw Power line with plug Halogen Lamp Centering Knob MIT300 Upright Metallurgical Microscope ...

Page 6: ... switch Fuse Input socket Output socket MIT300 Upright Metallurgical Microscope Camera adaptor with dust cover for trinouclar head tube Handle Stage up down adjusting screw Stage plate fix screw Coarse tension adjusting knob Left coarse focusing knob Left fine focusing knob ...

Page 7: ...izer adjusting ring and fixed screw Field diaphragm adjusting ring Condenser fixed screw Potentiometer MIT500 Transmitting Reflecting Metallurgical Microscope Clamp locking screw Power switch Power socket and Fuse Adjustable Level for swing out Condenser Condenser focusing knob ...

Page 8: ...wer house if transmitting observing operate the potentiometer and power switch in the microscope main body 2 Sample placing Choose an available stage plate put the sample onto it turn the stage knob to put the sample into the light path If reflection observing stage plate and glass plate should be chosen if transmitting observing glass plate and clamp should be chosen 3 Put 10X objective into ligh...

Page 9: ...wn adjusting screw after get the available position 10 Usage of 100X immersion oil objective Adding moderate immersion oil between the front lens of 100X objective and the cover glass of specimen can make the image clearer Please pay attention that air bubble and impurity can t be in the immersion oil otherwise the image would be affected First of all take 40X objective which has been focused well...

Page 10: ...avoid fungus and mist damage instrument 4 2 4 Please pay attention to prevent microscope from violent shake and vibration in application and in carrying Don t drag it on the surface of worktable to avoid damage to microscope and worktable 4 3 Replacement of bulb 4 3 1 Turn off power and pull out plug 4 3 2 Wait the bulb become cool Please be sure that the bulb is cool then follow by the nest opera...

Page 11: ...lass 0 17mm Cover glass of specimen isn t in up direction Place specimen correctly Surface of objective lens Is dirty especially it is easy for the front lens of 40X objective to dip in immersion oil Clean it Immersion oil isn t used for 100X objective oil Use immersion oil Immersion oil doesn t meet the requirement Use immersion oil supplied by us There is bubble in immersion oil Clear the bubble...

Reviews: