background image

PX-35                                                                              SSxxxxx   

 

Item 

Specification 

Remark 

Dedicated cradle 

For IrDA 
communication / 
charging 

Option 

Dedicated AC adapter [6V/2000mA] 

For charging 

 

*1 when scanning a barcode once per second at room tempe frequency of connecting to Bluetooth. 
*2 when scanning a barcode twice in 10 seconds at room tempe frequency of connecting to Bluetooth. 
*3 Shock resistance 

Conditions of the shock resistance test are:   

 

Does not count scratches or whitening on a surface as a malfunction.   

 

Shock resistance is approved when no malfunction occurs after the test.   

 

Shock resistance is approved if the battery cover is not unhooked after the test 

Summary of Contents for PX-35

Page 1: ...with Bluetooth Product Name PX 35 Specification No SSxxxxx Edition Initial release Date of Publication Dec 6 2010 Original Doc No SS10016 OPTOELECTRONICS Co Ltd 4 12 17 Tsukagoshi Warabi shi Saitama 335 0002 Japan TEL 81 0 48 446 1183 FAX 81 0 48 446 1184 ...

Page 2: ...PX 35 SSxxxxx Revision History Specification No SSxxxxx Product name PX 35 Revision Date Section Description of Changes Initial release 2010 12 6 ...

Page 3: ...Features 2 4 Basic Specifications 4 5 Optical Specifications 7 6 Technical Specifications 7 7 Bluetooth 11 8 Serial Label 12 9 Packaging Specifications 13 10 Durability 13 11 Warranty 16 12 Regulatory Compliance 17 13 RoHS 18 14 Precautions 18 Appendix 1 21 Appendix 2 22 ...

Page 4: ...t is compliant with RoHS 2 1 Product Model Name Product name PX 35 2 2 Features of PX 35 Compact and handy design The data collector is able to read 2D barcodes Stored data is sent to the recipient through Bluetooth interface On the other hand IrDA can communicate with host PC via the dedicated cradle Embedded Bluetooth is compliant to version 1 2 and has installed profile PX 35 can operate for a ...

Page 5: ...PX 35 SSxxxxx 2 3 Physical Features 3 1 Dimensions Figure1 Dimensions 3 2 Weight Max 132g including lithium ion battery pack 140 44 26 単位 mm Unit mm ...

Page 6: ...d operational items 5 Trigger key Press when scanning barcodes 6 Up Down keys Used when selecting items from a menu 7 10 operational keys Used for numerical ENTER decimal point input 8 DC Jack Used for the dedicated power supply 9 Speaker 10 Terminals Used to charge a lithium ion battery of a unit when placing the unit on the dedicated terminal 11 Battery cover Remove when replacing the rechargeab...

Page 7: ...file SPP Stack produced by iAnywhere Frequency 2402MHz to 2480MHz Transmission power Class 2 Communication range Perspective 10m Communication range may differ due to the environments Baud rate 115 2kbps Bluetooth Antenna 1 4λ surface mounted IrDA IrDA Ver1 2 physical layer compliant Baud rate Maximum 115 2Kbps Main power Lithium ion secondary battery 1880mAh Regular voltage 3 7V How to charge Wit...

Page 8: ...leaved 2 of 5 NW 7 CODABAR Code 39 Code 93 Code 128 GS1 128 Tri Optic MSI Plessey UK Plessey TELEPEN S Code Code 11 Matrix2 of 5 Korean Postal Authority code CODABLOCK F GS1 DataBar Dimensions 140 44 26mm Weight Max 132g including lithium ion battery pack Operation temperature and humidity 10 C to 40 C 20 RH to 85 RH No frost no condensation Storage temperature and humidity 20 C to 60 C 20 RH 85 R...

Page 9: ...y of connecting to Bluetooth 2 when scanning a barcode twice in 10 seconds at room temperature frequency of connecting to Bluetooth 3 Shock resistance Conditions of the shock resistance test are Does not count scratches or whitening on a surface as a malfunction Shock resistance is approved when no malfunction occurs after the test Shock resistance is approved if the battery cover is not unhooked ...

Page 10: ... source 3 wave lengths inverter fluorescent Angles α 0 β 15 γ 0 Curvature R Power supply voltage 3 3V Decoding test Approve the performance when decoding is successful in 70 of ten tests performed Barcode sample As specified below Bar Code Resolution Barcode PCS Size mm Digit 0 254mm Code 39 0 9 14 10 2 0 1mm Code 39 0 9 11 10 4 0 26mm JAN 13 0 9 25 19 13 0 26 mm JAN 8 0 9 17 5 15 5 8 Barcode samp...

Page 11: ... 40 Barcodes printed by a normal printer As for the size of each barcode quiet zone length is excluded 6 1 Decode Depth of Field and Resolution The depth of decode field is measured from the case front the data collector 単位 mm 40 Code39 JAN13 PDF417 Data Matrix Micro QR Code QR Code 100 200 300 400 35 110 35 220 110 900 45 320 35 110 220 35 190 35 90 35 140 35 100 分解能 0 127 分解能 0 254 分解能 1 0 分解能 0...

Page 12: ... R For pitch tilt angles skew angle β 15 Figure4 Pitch skew and tilt When scanning symbologies printed on highly glazed paper such as glossy paper or card case scanning performance of this data collector may decline due to the specular reflection of LEDs In such cases adjust scanning angle by incline the data collector to 15 degrees toward the skew direction to improve scanning performance When tu...

Page 13: ...5 mm With 13 digit JAN barcode decoding performance is guaranteed when R 20 mm Conditions Barcode sample Code 39 PDF417 Resolution 0 254mm PCS0 9 as specified in the section 6 Distance 63mm from the focal plane of the data collector Curvature R For pitch tilt angles skew angle β 15 Figure5 Curvature ...

Page 14: ...led Profile SPP Serial Port Profile 7 2 Communication Configuration 1 to 1 One data collector to one host system 7 3 Operating Mode While Connected to the Host System Master slave mode 1 1 It can be set by the application software 7 4 Security Mode Authentication enabled 7 5 Encryption Encryption enabled ...

Page 15: ...PX 35 SSxxxxx 12 8 Serial Label The labels shown below are affixed to the data collector 生産年 生産月 印刷色 黒 シリアルNo 印刷色 黒 H 5 H 7 H 5 文字 ロゴ 印刷色 黒 Figure 7 Serial label and FCC caution label ...

Page 16: ... 1 Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values Incandescent light 10 000 lx Fluorescent light 10 000 lx Sunlight 1000 000 lx Conditions Barcode sample Code39 Resolution 0 254mm PCS0 9 as specified in the section 6 Distance 63mm from the focal plane of the data collector Angles α 0 β 15 γ 0 Cu...

Page 17: ...irection once for 60 minutes each 10 5 Drop Test without packaging No malfunction occurred after the following test Drop test Drop the data collector from a height of 150cm onto a concrete floor Three times in each of 6 angles Figure 9 Drop Test without packaging 10 6 Drop Test with individual packaging No malfunction occurred after the following test Drop test Drop an individually packaged data c...

Page 18: ...unction 15 kV max No destruction Contact discharge 6 kV max No malfunction 10 kV max No destruction Measurement environment Use electrostatic testing device compliant with IEC 61000 4 2 Discharge resistance 330 Ω Capacitor charging 150 pF 10 8 Reliability MTBF 10 000 hours ...

Page 19: ...he foregoing warranty period 11 2 Delivery Products for maintenance or repair shall be sent back to Optoelectronics The sender is responsible for all shipping costs 11 3 Repair Timeframe Repaired products shall be shipped back to the customer within 20 days after acceptance by OPTOELECTRONICS However the time needed for the repair of products with early failures need to be separately discussed wit...

Page 20: ...B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used according to the instructions may cause harmful interference to radio communications However there is no guarantee that interfere...

Page 21: ...tification for Construction Design of Specified Radio Equipment Therefore it does not need to have a radio station license in Japan The following activities are prohibited under the Radio Law Remodeling and disassembly Peeling off the certificate label Do NOT use the data collector under the following environment Otherwise radio interference may affect other device and end up with causing physical...

Page 22: ...on Regulations This product is subject to the strategically controlled exports regulated under Foreign Exchange and Foreign Trade Laws Therefore export of this product may require an export permission of Japanese government 14 5 Bluetooth To communicate via Bluetooth the device which PX 35 is connected to must support the same Bluetooth version and profile as PX 35 s PX 35 is compliant to Bluetoot...

Page 23: ... identification requiring license for such as manufacturing lines at factories specific power saving radio station requiring no license and amateur radio station are managed Please make sure that other radio stations are not managed in the frequency band 2 4 GHz before using this scanner In case that radio interference occurs between this scanner and other radio stations change the service space i...

Page 24: ...PX 35 SSxxxxx 21 Appendix 1 Individual Packaging Specification BATTERY BTR040x Quick Start Guide PX 35019062 0 00 PX 35 XF1PX35 ...

Page 25: ...PX 35 SSxxxxx 22 Appendix 2 Collective Packaging Specification PX 35 XF1PX35 FM42J ...