19
Adjusting the image position and focus
After the UST lens is installed, turn on the projector and adjust the image position.
1. Place the projector as close as possible to the screen.
2. Turn on the projector.
3.
To display a test pattern, press the “Pattern “key on the remote control.
The test image could be out of focus and the bottom edge may appear obscured or in dark.
4.
To
remove the obscured bottom edge, adjust the image position by pressing the “Lens V“ keys to
shift the image up or down.
Note:
To prevent product damage, avoid over adjusting the lens position as the UST lens boresight
plate allows limited lens shift range.
5.
If the obscured edge still exists after the lens shift, adjust the vertical position of the two M3 x L8 hex
screws connecting the lens bracket and the lens support assembly, which mechanically moves the
image up or down. Use a 2.5 mm allen key to adjust the M3 hex screws.
6.
To adjust
the image focus, press the “Zoom“ keys to adjust the back focus and the “Focus“ keys to
adjust the focus.