Rev. 00
Company Confidential Optoma_______________________ Delta____________
16
2008/07/02
Confirmation with none-signal state
Projector logo
screen display
• CW Sensor Board Ass’y malfunction
• Main Board Ass’y malfunction
• DMD Set malfunction
Still dark after the
lamp is on for
more than 1min
• Lamp deterioration (malfunction/usage time)
• Power Supply Unit malfunction
(No change occurs even after lamp replacement.)
• DMD Set malfunction
(No change occurs even after lamp replacement.)
Menu display
• Remote controller set malfunction, Low battery,
and outside operation rang
• Main Board Ass’y malfunction
• Connector (CN451)
、
(CN101 of IR PWB) disconnected
• IR PWB Ass’y malfunction
• Check the pattern generator setting is wrong
• Main Board Ass’y malfunction
• DMD Set malfunction
• Setting on PC side(external output setting, resolution, etc.)
• Cable malfunction (disconnection and pins broken)
• Connector (CN705)
、
(CN8 of IO BD) disconnected
• Connector (CN704) disconnected
• Speaker Ass’y malfunction
• Main Board Ass’y malfunction
• IO Board Ass’y malfunction
Check the
projection
Screen
Image display
normally
Input each signal
Speaker work
normally
Image
Display
Yes
No
No
No
Yes
No
Yes
Yes
No
Yes
Yes
Yes
No
No
No
No
No