EzPro 710 6-1
Service Manual
EzPro710
Service Manual
6.1 Product :
q
EP 710 Projector
6.2 Test Equipment :
q
Color Video Signal & Pattern (or PC with XGA resolution)
q
Hi-pot & Grounding measurement
q
25X Monoscope or Blemish film
Minolta CL-100 Chroma meter
6.3 Test Condition:
Before function test and alignment, each Projector
should be run-in and warmed-up for at least 2 hours with
the following conditions:
a). In room temperature,
b). With full-white screen,
c). With cycled display modes,
640*350 (H=31.47kHz, V=70.09Hz)
640*480(H=31.47kHz, V=59.94Hz)
800*600 (H=46.9kHz, V=75Hz)
1024*768 (H=48.4kHz, V=60Hz)
1024*768 (H=56.5kHz, V=70Hz)
1024*768 (H=60kHz, V=75Hz)
Chapter 6
Function Test & Alignment Procedure