6.5 Function Test and Alignment Procedure
6.5.1 All Mode Reset
Please press “+” and “-” functions on front bezel and trun on Power
simultaneously and keep unreleased for 2 seconds. Then, the screen will show
“ALL MODES RESET”. This action will allow you to erase all end-user’s setings
and restore the factory defaults.
6.5.2 Auto Adjustment
Please select and enter “Auto Adjustment” function on Main Menu to see
if it is workable.The “Auto Adjustment” function is aimed to offer a better screen
quality by built-in ASIC. For optimum screen quality, the user has to adjust each
Function manually.
6.5.3 Frequency and Tracking
Test Signal : 1024*768@75Hz
Test Pattern : Line MoirePattern
Check and see if the image sharpness and focus is well performed.
If not, readjust by the following steps :
(a) Select and enter “Frequency” function on “Advanced Menu” to adjust
the screen to full screen and to eliminate visual wavy noise.
(b) Then, select and enter “Track” function to adjust the image to eliminate
visual noise.
(c) Be sure to select and enter “Save and Return” to save the changes.