8.2 Lamp Specifications
v
Temperature
Lamp driver ambient temp
< 50
o
C, forced air cooling
Lamp driver Max. temp at test point <= 80
o
C
Lamp side connector
120
o
C Max. (at any rotated position)
Lamp central connector
200
o
C Max.
Lamp environmental temp
< 85
o
C to be measured 20mm above
reflector neck.
v
Typical burner characteristics (initial)
v
Typical burner characteristics (initial)
Lamp life time:
1000h
According to the actual test results, based
on a lamp survival rate of >50%. Will
continuously be adapted due to ongoing
efforts.
Integral lumen
maintenance
70% typ
At end of life
v
Rise time
Rise time to 80% of the stabilized luminous output is < 90 sec.
v
Hot restrike
<= 60 sec. (Ignition voltage 20KV +-3KV), goal 30 sec.
Thermal: Fans may be switched on after lamp has been switched off.
v
Environmental requirements
Storage temperature:
-40
o
C to 65
o
C
Operating temperature:
0
o
C to 45
o
C
UV-output UVA
(315-400 nm) 5W nom
UVB
(280-315 nm) < 0,1W
UVC
(248-280 nm) < 0,01W
Total visible Flux
(400-780 nm) 30W nom
IR