English 67
aDDITIonal InfoRmaTIon
Warning indicators
When the warning indicators (see below) light up or flash, the projector will automatically shutdown:
"LAMP" LED indicator is lit red and if "On/Standby" indicator flashes amber.
"TEMP" LED indicator is lit red and if "On/Standby" indicator flashes amber. This indicates the
projector has overheated. Under normal conditions, the project can be switched back on.
"TEMP" LED indicator flashes red and if "On/Standby" indicator flashes amber.
Unplug the power cord from the projector, wait for 30 seconds and try again. If the warning indicator light up or
flash, please contact your nearest service center for assistance.
lED lightning messages
Message
Power LED
Power LED
Temp-LED
Lamp-LED
(Red)
(Green or Blue)
(Red)
(Red)
Standby state
(Input power cord)
Steady light
Power on (Warming)
Flashing
(0.5 sec off /
0.5 sec on)
Power on and Lamp
lighting
Steady light
Power off (Cooling)
Flashing
(0.5 sec off /
0.5 sec light). Back
to red steady light
when cooling fan
turns off.
Quick Resume (100
secs)
Flashing
(0.25 sec off /
0.25 sec light)
Error (Over temp.)
Flashing
Error (Fan failure)
Flashing
Flashing
Error (Lamp failure)
Flashing
Power off:
Power Off?
Press Power key again
Lamp warning:
Lamp Warning
Lamp life exceeded.
Summary of Contents for HD28DSE