26
-
2.10 Measurement specifications [F2/ F6/ P7 models]
F2H
F6
F6H
P7
Temperature range (scalable)
400...1650 °C
200...1450 °C
400...1650 °C
0…710 °C
Spectral range
4.24 µm
4.64 µm
7.9 µm
Optical resolution
45:1
System accuracy
2), 4)
(at ambient
temperature 23
5 °C)
±1 %
3)
±1.5 °C or ±1 %
1)
Repeatability
1), 2)
(at ambient
temperature 23
5 °C)
±0.5 °C or ±0.5 %
2)
Temperature resolution (NETD)
0.1 K
0.5 K
Response time (90 % signal)
10 ms
150 ms
Emissivity/ Gain
0.100...1.100 (adjustable via programming keys or software)
Transmissivity
0.100...1.000 (adjustable via programming keys or software)
Signal processing
Average, peak hold, valley hold (adjustable via programming keys or software)
1)
Whichever is greater,
2)
= 1/ Response time 1s,
3)
at object temperatures >300 °C,
4)
Accuracy for thermocouple output: ±2.5 °C or
±1
%,
whichever is greater
Summary of Contents for CTlaser 05M
Page 1: ...Operator s Manual optris CTlaser LT LTF 05M 1M 2M 3M MT F2 F6 G5 P7 Infrared thermometer...
Page 8: ...8 Appendix C Smart Averaging 96 Appendix D Declaration of Conformity 97...
Page 44: ...44 Figure 2 Mounting bracket adjustable in one axis Order No ACCTLFB standard scope of supply...
Page 45: ...Mechanical Installation 45 Figure 3 Electronic box...
Page 97: ...Appendix D Declaration of Conformity 97 Appendix D Declaration of Conformity...
Page 98: ...optris CTlaser E2018 12 A...