86
-
7.2 Communication settings
For further information see protocol and command description on the software CD
CompactConnect in the directory:
\Commands
.
7.2.1 Serial Interface
Baud rate:
9.6...115.2 kBaud (adjustable on the unit or via software)
Data bits:
8
Parity:
none
Stop bits:
1
Flow control
off
7.2.2 Protocol
All sensors of the CTlaser series are using a binary protocol. Alternatively they can be switched to an ASCII
protocol. To get a fast communication the protocol has no additional overhead with CR, LR or ACK bytes.