optris LS – E2006-01-A
7
Measurement Functions
The measured temperature will be shown in the main display
[1]
. In the upper
display the according maximum temperature
[2]
and in the lower display the set
emissivity
[3]
will be displayed. The bar graph in the right part of the display
[4]
shows temperature trends. The scaling will be done automatically between
minimum reading (no segment) and maximum reading (all segments).
Hold function
: The temperature will be displayed for
7 seconds
after the
Trigger
is released. The display shows
HOLD
. The unit automatically switches off after this
time if no button is pressed.
After taking a measurement the following functions can be displayed in turn by pressing the
Λ
-button (starting
from the
HOLD
mode):
Maximum reading [MAX]
Minimum reading [MIN]
Average reading [AVG]
Difference reading [DIF]