4.7 Connecting two amplifiers
4.7.1 Master over 1 Slave
To expand and duplicate an installation or to use a low spill system or high coverage system with the LD Series
1-channel amplifiers:
1. Connect the loops to the terminals provided: amplifier Loop terminal.
2. Insert an audio source into INPUT 1, 2 or 3 of the master amplifier.
3. Connect the OUT 90° output of the Master amplifier to the Slave amplifier using a 6.35mm link cable.
4. Turn on the amplifiers and adjust them accordingly.
4.7.2 Slave to slave
Connect the OUT jack (0° or 90°) of the slave loop amplifier to the IN jack of the next slave loop amplifier.
This allows you to connect several slave amplifiers. (See diagram on next page)
This allows you to use multiple amplifiers on the same input. This can be useful for very large rooms or if several
rooms share the same audio transmission.
90° output to Slave
amplifier
OUT
16
Master amplifier
Slave amplifier
Input on slave amplifier
IN
LD Series | Installation and user manual
User manual