7
5. Plumbing
The Opus Calypso is supplied ‘system fit’, so connecting to existing pipe work should be
straight forward. The Calypso has been designed and built for both open vent and
pressurised heating and hot water systems, incorporating an over heat quench coil with
built in quench valve to prevent the boiler over heating.
The flow and returns must be connected to a pumped circuit. The Calypso is not designed
for a thermo-syphon type circuit. The use of an LK810 thermomat load unit (or similar) is
strongly recommended.
For optimum performance, it is recommended that the Calypso is piped to a thermal store.
5.1 Connections
To access the pipe work, the rear panel must first be removed from the stove. Remove the
stove top, unscrew the two hex head bolts on either side at the top of the panel, and lift
panel away from stove.
I
Over heat coil discharge
II
Primary flow
III
Primary return
IV
Cold mains connection for over
heat coil
V
Pressure relief valve
VI
Manual bleed vent
VII ¾” BSPF (optional connection)
VIII Over heat valve sensor
Summary of Contents for Calypso