MBE 300 • User guide
GB
POSSIBLE PROBLEMS
CALIBRATION PROCESS
Press and hold COUNTER button for 15 seconds until, Calibration is shown
on LCD screen. Next press and hold both START buttons and do not take your
fi ngers of the buttons until it stops.
MAINTENANCE
The equipment does not require any lubrication or periodic checks. Places
that need to be oiled are oiled and sealed during the manufacturing process at the
production stage. The cover of the equipment is powder coated and baked hard.
To clean the equipment you can use general household cleaning products.
Do not use solvents or petroleum-based products.
PROBLEM
CAUSE
SOLUTION
Display does not work.
The plug is not connected to the socket.
Lack of power in the socke.
Equipment damage.
Connect the plug to the socket
correctly.
Check main fuse or connect to diff e-
rent socket.
contact the supplier.
The motor moving the
jaw does not work.
The motor has overheated.
(see the LED display for information)
Equipment damage.
Wait for the motor to cool down (5 to
15 minutes) (see the LED display for
information).
Contact the supplier.
The equipment works
but does not bind
properly.
The pressure setting is too low.
Equipment damage.
Set a higher binding pressure.
Contact the supplier.
The equipment works
but the jaw stops
intermittently while
moving without any
reason.
Higher resistance values.
Re-calibrate, follow the instructions
in the user’s guide. If the problem
remains, contact the supplier.
13