Power Events
Messages and Descriptions
Component Name
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A voltage sensor reported that its value went above an upper
fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap:
sunHwTrapVoltageFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A voltage sensor reported that its value went below an
upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap:
sunHwTrapVoltageCritThresholdExceeded
Oracle ILOM Event Message:
Upper critical threshold exceeded
Severity and Description:
Critical; A voltage sensor reported that its value went above an upper
critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap:
sunHwTrapVoltageCritThresholdDeasserted
Oracle ILOM Event Message:
Upper critical threshold no longer exceeded
Severity and Description:
Informational; A voltage sensor reported that its value went below an
upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap:
sunHwTrapVoltageNonCritThresholdExceeded
Oracle ILOM Event Message:
Upper noncritical threshold exceeded
Severity and Description:
Minor; A voltage sensor reported that its value went above an upper
noncritical threshold setting or below a lower noncritical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap:
sunHwTrapVoltageOk
Oracle ILOM Event Message:
Upper noncritical threshold no longer exceeded
Severity and Description:
Informational; A voltage sensor reported that its value is in the
normal operating range.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap:
sunHwTrapSensorNonCritThresholdExceeded
Oracle ILOM Event Message:
Upper noncritical threshold exceeded
/SYS/VPS_CPUS
/SYS/VPS_MEMORY
274
Oracle Exadata Storage Server X7-2 EF and HC Service Manual • May 2018
Summary of Contents for Exadata Storage Server X7-2 EF
Page 1: ...Oracle Exadata Storage Server X7 2 EF and HC Service Manual Part No E72479 06 May 2018 ...
Page 2: ......
Page 12: ...12 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 14: ...14 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 80: ...80 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 110: ...110 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 118: ...118 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 136: ...136 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 144: ...144 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 152: ...152 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 158: ...158 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 172: ...172 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 186: ...186 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 194: ...194 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...
Page 230: ...230 Oracle Exadata Storage Server X7 2 EF and HC Service Manual May 2018 ...