Table 1-6 (Cont.) Environmental Requirements for Oracle Exadata Database
Machine X3-2
Environmental
Component
Oracle Exadata
Database
Machine X3-2
Full Rack
Oracle Exadata
Database
Machine X3-2
Half Rack
Oracle Exadata
Database
Machine X3-2
Quarter Rack
Oracle Exadata
Database
Machine Eighth
Rack
IP Addresses
See Also:
"
Connection and
IP Address
Requirements for
Oracle Exadata
Database
Machine
(page 1-47)"
69 for Ethernet
network,
assuming single
cluster
22 for InfiniBand
network
39 for Ethernet
network,
assuming single
cluster (39 IP
addresses are
needed for
Oracle Exadata
Database
Machine X2-2
(with X4170 and
X4275 servers))
11 for InfiniBand
network
22 for Ethernet
network,
assuming single
cluster
5 for InfiniBand
network
22 for Ethernet
network,
assuming single
cluster
5 for InfiniBand
network
Network drops
See Also:
"
Connection and
IP Address
Requirements for
Oracle Exadata
Database
Machine
(page 1-47)"
Minimum of 11
network drops
Minimum of 7
network drops
Minimum of 5
network drops
Minimum of 5
network drops
External
connectivity
See Also:
"
Connection and
IP Address
Requirements for
Oracle Exadata
Database
Machine
(page 1-47)"
24 x 1 GbE/10
GbE Ethernet
ports
16 x 10 GbE
Ethernet ports
At least 12
InfiniBand ports
12 x 1 GbE/10
GbE Ethernet
ports
8 x 10 GbE
Ethernet ports
At least 12
InfiniBand ports
6 x 1 GbE/10
GbE Ethernet
ports
4 x 10 GbE
Ethernet ports
At least 12
InfiniBand ports
6 x 1 GbE/10
GbE Ethernet
ports
4 x 10 GbE
Ethernet ports
At least 12
InfiniBand ports
1.1.8 General Environmental Requirements for Oracle Exadata
Database Machine X3-8 Full Rack with Exadata Storage Server X4-2L
Servers
(page 1-15) shows the general environmental requirements for Oracle
Exadata Database Machine X3-8 Full Rack with Exadata Storage Server X4-2L
Servers. The other sections in this chapter provide detailed information.
Chapter 1
General Environmental Requirements
1-14