Remove a DIMM
.
Check the
Fault class
and
Description
fields for more information.
If a DIMM is faulty, replace it. See
7.
If you are unable to determine if a DIMM is faulty, seek further information.
“Detecting and Managing Faults” on page 21
Related Information
■
■
“DIMM Configuration” on page 182
■
■
“Detecting and Managing Faults” on page 21
Remove a DIMM
Removing a DIMM is a cold-service operation. You must power off the server before you
remove the DIMM.
1.
Determine which DIMM to remove.
“Locate a Faulty DIMM” on page 185
.
2.
Consider your next step.
■
If you have not prepared for service, do so now. See
“Preparing for Service” on page 61
.
■
If you are removing a DIMM as part of another component's removal or installation
3.
Review this information and complete these prerequisites in this order.
■
“Rotate the Drive Cage to the Service Position” on page 82
■
“Remove the Air Duct” on page 83
4.
Locate the DIMM to remove.
Servicing DIMMs
187
Summary of Contents for netra X5-2
Page 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Page 2: ......
Page 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Page 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Page 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Page 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Page 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Page 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Page 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Page 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Page 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Page 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Page 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Page 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Page 274: ...274 Netra Server X5 2 Service Manual October 2016 ...