Using the Server Fault Remind Button
Note -
You can enable the Locator LED to blink with the
set /SYS/LOCATE value=Fast_Blink
command.
Component LED state
Target
Comment
Locator
/SYS/LOCATE
Chassis Ok
/SYS/OK
Chassis Service
/SYS/SERVICE
CPU P
x
Service
/SYS/MB/P
x
/SERVICE
where
x
is either
0
or
1
Drive HDD
x
Ok to Remove
/SYS/DBP/HDD
x
/OK2RM
where
x
is
0
to
7
Drive HDD
x
Service
/SYS/DBP/HDD
x
/SERVICE
where
x
is
0
to
7
Fan module FM
x
Service
/SYS/MB/FM
x
/SERVICE
where
x
is
0
to
4
Power supply Fault
/SYS/PS_FAULT
SP Ok
/SYS/SP/OK
DIMM D
y
/SYS/MB/P
x
/D
y
/SERVICE
where
y
is
0
to
11
, and
x
0
or
1
Critical alarm
/SYS/CRITICAL_ALARM
Major alarm
/SYS/MAJOR_ALARM
Minor alarm
/SYS/MINOR_ALARM
User alarm
/SYS/USER_ALARM
Related Information
■
“Oracle ILOM Legacy Targets for Component FRUID and Fault States” on page 53
■
“Oracle ILOM Legacy Targets for Component Power Consumption” on page 55
■
“Display Component LED State” on page 57
Using the Server Fault Remind Button
When the server Fault Remind button is pressed, an LED located next to the Fault Remind
button lights green to indicate that there is sufficient voltage present in the fault remind circuit
to light any fault LEDs that were lit due to a component failure. If this LED does not light when
you press the Fault Remind button, it is likely that the capacitor powering the fault remind
circuit has lost its charge. This can happen if the Fault Remind button is pressed for several
minutes with fault LEDs lit or if power has been removed from the server for more than 15
minutes.
Fault LEDs are provided on the motherboard for DIMMs, fan modules, and CPUs. The figure
shows the location of the Fault Remind button and LED.
58
Netra Server X5-2 Service Manual • October 2016
Summary of Contents for netra X5-2
Page 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Page 2: ......
Page 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Page 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Page 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Page 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Page 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Page 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Page 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Page 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Page 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Page 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Page 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Page 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Page 274: ...274 Netra Server X5 2 Service Manual October 2016 ...