Locate a Faulty DIMM
Related Information
■
“DIMM Configuration” on page 182
■
Locate a Faulty DIMM
You must determine which DIMM is faulty before you replace it.
1.
Check to see if any System Service Required LEDs are lit or flashing.
“Interpreting Diagnostic LEDs” on page 30
.
2.
In Oracle ILOM, check the health of the memory system.
->
show /System/Memory
/System/Memory
Targets:
Properties:
health = OK
health_details = -
...
->
If the
health_details
property identifies a faulty DIMM, replace it. See
.
Servicing DIMMs
185