Connect Cables
The SP serial management port is labeled SER MGT. Use the SER MGT port
only
for server
management. This port is the default connection between the SP and a terminal or a computer.
When connecting a DB-9 cable, use an adapter to perform the crossovers given for each
connector.
a.
Configure a terminal or terminal emulator with these settings:
■
9600 baud
■
8 bits
■
No parity
■
1 Stop bit
■
No handshake
A null modem configuration is needed, meaning the transmit and receive signals are
reversed (crossed over) for DTE to DTE communications. You can use the supplied RJ-45
crossover adapters with a standard RJ-45 cable to achieve the null modem configuration.
52
SPARC T8-1 Server Installation Guide • June 2019