Servicing the SPM
These topics describe how to service the SPM.
■
“SPM Firmware and Configuration” on page 121
■
■
■
SPM Firmware and Configuration
System firmware consists of two components, an SP component and a host component. The
SP firmware component is located on the SPM, and the host component is located on the
motherboard. For the server to operate correctly, the firmware in these two components must be
compatible.
When replacing the SPM, you must restore the configuration settings maintained in the SPM.
Before replacing the SPM, save the configuration using the Oracle ILOM backup utility. Refer
to the Oracle ILOM documentation for instructions on backing up and restoring the Oracle
ILOM configuration.
After replacing the SPM, the new SPM firmware component and the existing host
firmware component must be consistent with each other. To ensure that the firmware is
compatible throughout the server, load new system firmware as described in
Related Information
■
Oracle ILOM documentation
■
“Servicing the Motherboard” on page 129
■
■
Servicing the SPM
121
Summary of Contents for SPARC T8-1
Page 1: ...SPARC T8 1 Server Service Manual Part No E80510 04 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 1 Server Service Manual January 2022 ...
Page 20: ...20 SPARC T8 1 Server Service Manual January 2022 ...
Page 58: ...58 SPARC T8 1 Server Service Manual January 2022 ...
Page 106: ...106 SPARC T8 1 Server Service Manual January 2022 ...
Page 112: ...112 SPARC T8 1 Server Service Manual January 2022 ...
Page 128: ...128 SPARC T8 1 Server Service Manual January 2022 ...
Page 146: ...146 SPARC T8 1 Server Service Manual January 2022 ...
Page 152: ...152 SPARC T8 1 Server Service Manual January 2022 ...