Chapter 3
Servicing Server Module Components
3-25
3.4
Replacing the SP (FRU)
This section provides instructions for replacing a damaged service processor (SP)
unit.
Before You Begin
■
If you are replacing an SP board that is not dead, obtain the ILOM version and
download the system software release package (combined BIOS/ILOM) that
incorporates that version. A system software release package can be downloaded
from:
http://support.oracle.com
.
■
If you are replacing a dead SP board, obtain the BIOS version and download the
system software release package (combined BIOS/ILOM) that incorporates that
version. A system software release package can be downloaded from:
http://support.oracle.com
.
1. Prepare the server module for service.
a. Power off both server module compute nodes.
See
Section 2.4, “Powering Off the Server Module” on page 2-4
.
b. Remove the server module from the Sun Blade chassis. Place it on a flat
surface.
See
Section 2.5, “Removing the Server Module From the Sun Blade Chassis” on
page 2-7
.
c. Attach an antistatic wrist strap.
See
Section 2.6, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9
.
d. Remove the server module top cover.
See
Section 2.7, “Removing the Server Module Top Cover” on page 2-11
.
2. Remove the new service processor from its shipping container and place it on
an antistatic surface.
3. Remove the three screws that fasten the old service processor to the
motherboard (
FIGURE 3-13
).
Summary of Contents for Sun Blade X6275
Page 1: ...Sun Blade X6275 Server Module Service Manual Part No Part No 820 6849 16 September 2013 Rev A ...
Page 26: ...1 16 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 47: ...Chapter 3 Servicing Server Module Components 3 7 FIGURE 3 3 DIMM Numbering and Position ...
Page 61: ...Chapter 3 Servicing Server Module Components 3 21 FIGURE 3 11 Removing a Processor ...
Page 80: ...3 40 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 86: ...4 6 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 112: ...A 26 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 116: ...Index 4 Sun Blade X6275 Server Module Service Manual September 2013 ...