86
Sun Datacenter InfiniBand Switch 648 Installation Guide • May 2010
■
“Access the CMC From the Serial Management Port” on page 82
■
“Management Cable Requirements” on page 9
■
“Network Management Connector and Pins” on page 4
▼
Verify the CMC Status
You can use the
clia shmstatus
command to check the status of the CMCs.
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
.
2. On the CMC, type:
If the output displays
Host: Inactive
, use the
clia switchover
command to
activate the CMC.
3. Check the status of the I
2
C bus components:
If any test failed, use the
switchover
command to activate the other CMC and
cable it for the rest of the installation process.
#
clia shmstatus -v
Pigeon Point Shelf Manager Command Line Interpreter
Host: "Active"
Ready For Operation: Yes
Detailed State Flags: "Shelf FRU Found" "RMCP Up"
#
#
i2ctest
M9 CMC I2C access test started:
I2C test of ADM1026 at bus 3 addr 2e -PASSED
I2C test of PCA9506 at bus 2 addr 21 -PASSED
I2C test of PCA9506 at bus 2 addr 24 -PASSED
I2C test of PCA9548 at bus 2 addr 71 -PASSED
I2C test of PCA9555 at bus 2 addr 20 -PASSED
I2C test of AT64C24 at bus 2 addr 57 -PASSED
M9 CMC I2C access test PASSED
#