102
Sun Datacenter InfiniBand Switch 648 Installation Guide • May 2010
Related Information
■
“Understanding the Installation” on page 15
■
“Powering On the CMCs” on page 75
■
“Powering On the Fabric Cards” on page 92
▼
Enable the Line Cards for Installation
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
.
2. Enable standby power and the IPMB buses for the line cards on the CMC:
where
slot
is the slot number of the installed line cards (
0
–
8
).
3. Repeat
for each installed line card.
4. Verify that the OK LED flashes on the line cards that have been enabled.
If the OK LED is not flashing on the enabled line cards, investigate why. See
“Check the Line Card Status LEDs” on page 103
5. Power on the line cards.
See
“Power On the Line Cards for Installation” on page 103
Related Information
■
Switch Command Reference
,
enablestby
command
■
“Enable the Fabric Cards for Installation” on page 93
5.
Identify line card addresses.
“Identify the Line Card Addresses” on
page 106
6.
Display line card FRU ID
information.
“Display the Line Card FRU ID
Information” on page 107
#
enablestby lc
slot
Step
Description
Links