Sun Datacenter InfiniBand Switch 648 Installation Guide • May 2010
Related Information
■
“Understanding the Installation” on page 15
■
“Powering On the Fabric Cards” on page 92
■
“Powering On the Line Cards” on page 101
▼
Attach the Management Cables
Each CMC has 3 RJ-45 connectors for serial management, debug, and network
management.
The serial management connector, labeled SER MGT, is the initial interface from the
management console to the CMC. The management console can be a serial terminal,
a system running a TIP connection, or other serial device. Once communication with
the CMC is established, the CMC can be configured to use the network management
connector, labeled NET MGT.
The NET MGT connector is a 100 BASE-T Ethernet interface and is preferred because
it permits remote management of the CMC over the network. To have the same
functionality with the SER MGT connector, a terminal server would need to be
configured.
The debug connector permits low speed serial direct access to the IPMB controllers of
each fabric card and line card.
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
.
2. Connect the serial management cables from the management console to the
connectors labeled SER MGT.
9.
Verify the power supply status.
“Verify the Power Supply Status” on
page 89
10.
Identify the power supply addresses.
“Identify the Power Supply Addresses” on
page 90
11.
Display the power supply FRU ID
information.
“Display the Power Supply FRU ID
Information” on page 91
Step
Description
Links