Remove FB-DIMMs
Chapter 4 • Replacing Motherboard Assembly Components
103
Faulty FB-DIMMs are identified with a corresponding amber LED on the motherboard.
Note -
The FB-DIMM fault LEDs remain lit only for a few minutes.
5.
Ensure that all FB-DIMMs are seated correctly in their slots.
Remove FB-DIMMs
1.
Prepare the server for FB-DIMM removal. See:
■
“Power Off the Server” on page 59
■
“Disconnect Cables From the Server” on page 60
■
“Remove the Server From the Rack” on page 60
■
“Perform Antistatic Measures” on page 61
■
“Remove the Top Cover” on page 62
■
“Remove the Memory Air Duct” on page 83
2.
If you are replacing a faulty FB-DIMM, locate the FB-DIMMs that you want to
replace. See
“Locating a Faulty FB-DIMM ” on page 101
3.
If you are removing a FB-DIMM on the motherboard, you must first
remove the memory mezzanine, see
4.
Push down on the ejector tabs on each side of the FB-DIMM until the
FB‐
DIMM is
released (
Caution -
FB-DIMMs may be hot. Use caution when servicing FB-DIMMs.
5.
Grasp the top corners of the faulty FB-DIMM and remove it from the server.