4.15 Replacing the Auxillary Board Assembly
126
Sun Netra T5440 Server • September 2015
4.
Place the SAS cable in its original position and plug it into the SAS expander.
5.
Install the PCI cards in slots 1-4.
See
“Install PCI-X 0-1 and PCIe 2-3 Cards” on page 76
and PCIe Cards 7-9” on page 79
.
6.
Install the hard drive fan assembly (Fan Tray 1).
See
“Install the Hard Drive Fan Assembly (Fan Tray 1)” on page 139
7.
Return the server to operation.
See
Chapter 6, “Returning the Server to Operation”
4.15 Replacing the Auxillary Board Assembly
This section describes how to remove and install the auxillary board assembly.
Caution -
This procedure must be performed by a certified Sun Oracle Service Technician only.
Remove the Auxillary Board Assembly
1.
Perform the following tasks to prepare the server for SAS expander assembly
removal:
■
“Power Off the Server” on page 59
■
“Disconnect Cables From the Server” on page 60
■
“Remove the Server From the Rack” on page 60
■
“Perform Antistatic Measures” on page 61
■
“Remove the Top Cover” on page 62
■
“Remove the Hard Drive Fan Assembly (Fan Tray 1)” on page 138
2.
Remove the PCI cards in slots 1-4.
Note each card position and external cabling before removing. See
and PCIe 2-3 Cards” on page 73
“Remove PCIe/XAUI Cards 4-6 and PCIe Cards
.
Summary of Contents for Sun Netra T5440