Install the FB-DIMM Fan Assembly (Fan Tray 2)
142
Sun Netra T5440 Server • September 2015
Install the FB-DIMM Fan Assembly (Fan Tray 2)
1.
Remove the replacement FB-DIMM fan assembly from its packaging and place it
on an antistatic mat.
2.
Reinsert the FB-DIMM fan assembly in the rear chassis slot.
FIGURE 5-10
Installing the FB-DIMM Fan Assembly
3.
Slide the FB-DIMM fan assembly in the slot until fully seated.
4.
Tighten the green FB-DIMM fan assembly captive screw.
5.
Chapter 6, “Returning the Server to Operation”
online:
5.6
Replacing the Power Board
To remove the power board, you must remove the following components as part of preparing
the server for power board replacement:
■
Memory mezzanine (see
“Remove the Memory Mezzanine Assembly” on page 98
)
■
“Remove the PCI Mezzanine Assembly” on page 86
)
Summary of Contents for Sun Netra T5440