10
Sun Network QDR InfiniBand Gateway Switch Service Manual for Firmware Version 2.1 • March 2013
■
y
is the fault sequence number (starting at
0
) for the target
x
.
For example:
The
class
property provides a general reason for the fault.
4. Use
faulted_target
to identify the component that has faulted and might need to
be replaced.
See
“Clearable Fault Targets” on page 11
.
Related Information
■
“Display Faulty Components (fault_state)” on page 8
■
“Clear a Fault Manually” on page 10
■
“Clearable Fault Targets” on page 11
▼
Clear a Fault Manually
If Oracle ILOM detects a fault and consequential component replacement, Oracle
ILOM automatically clears the fault. However, you can manually clear the fault after
replacing the component, if necessary.
1. Access the Oracle ILOM CLI.
See
“Access the Oracle ILOM CLI (NET MGT Port)” on page 35
.
->
show /SP/faultmgmt/0/faults/0
/SP/faultmgmt/0/faults/0
Properties:
class = fault.chassis.device.psu.fail
sunw-msg-id = DCSIB-8000-23
uuid = e8f7a292-62ab-43a2-9f32-30991cf8fbd5
timestamp = 2012-04-01/10:34:18
fru_part_number = 3002234
fru_serial_number = 006541
product_serial_number = AK00022680
chassis_serial_number = AK00022680
->