Detecting and Managing Faults
17
Related Information
■
“Display the General Alarm State of Systems and Components” on page 14
■
“System Alarm Targets” on page 15
■
“Component Alarm Targets” on page 15
Evaluating Sensor Alarms
These topics enable you to evaluate sensor information, to determine if an
unfavorable condition has occurred or will happen.
Alarm State
Description
cleared
The component or system has recovered from an alarmed condition and is fully
operational.
warning
An alarm has identified a condition that is abnormal, but does not affect any
individual component.
minor
An alarm has identified a condition that might affect an individual component.
major
An alarm has identified a condition that affects only the individual component. The
condition might affect a system, but not enough to compromise the operation of the
gateway.
critical
An alarm has identified a condition that affects both individual components and
systems. The operation of the gateway is compromised or at risk.
indeterminate
Oracle ILOM is unable to provide an alarm state for this component.
(none)
The component or its alarm is not available to Oracle ILOM. (The component might
have been removed.)