30
Sun Network QDR InfiniBand Gateway Switch Service Manual for Firmware Version 2.1 • March 2013
Related Information
■
“State Sensor Alarm Conditions” on page 30
State Sensor Alarm Conditions
The gateway has many sensors that check the state of a voltage, component, or
system fault, or voltage presence. In an acceptable state, the state sensors report a
value of
State Deasserted
, meaning no error. When a voltage, component, or
system goes to a detrimental state, the state sensors report a value of
State
Asserted
.
For example, when the state of sensor target
/SYS/FAN1/FAULT
is
State
Asserted
, there is a problem with fan 1.
Related Information
■
“Evaluate a State Sensor” on page 29
Evaluating a Presence Sensor Alarm
These topics help you resolve presence sensor alarms.
■
“Evaluate a Presence Sensor” on page 31
■
“Presence Sensor Alarm Conditions” on page 31
•
/SYS/MB/V_3.3VMainOK
•
/SYS/POWER_ATTN
•
/SYS/POWER_REDUN
•
/SYS/PSU
x
/ALERT
•
/SYS/PSU
x
/AC_PRESENT
•
/SYS/PSU
x
/FAULT
Replace the power supply.
“Servicing Power Supplies”
on page 41
•
/SYS/TEMP_ATTN
•
/SYS/COOLING_ATTN
•
/SYS/COOLING_REDUN
•
/SYS/FAN
x
/FAULT
Replace the fan.
“Servicing Fans” on page 55
•
/SYS/MB/BOOT_I4A
•
/SYS/IBDEV_ATTN
Check the I4 switch chip.
Refer to
Gateway
Administration
, resetting a
port.
All other state sensors.
Replace the gateway.
“Remove the Gateway From
the Rack” on page 77
State Sensor Target
Action
Links