Servicing Data Cables
73
Note –
On some QSFP cable connectors, there is a retraction strap. Both the
retraction strap and L groove indicate the reference surface for the connector. When
installing QSFP cables in the top row receptacles (0A, 1A, 2A, and so on), ensure that
the L groove and retraction strap are up. When installing QSFP cables in the bottom
row receptacles (0B, 1B, 2B, and so on) ensure that the L groove and retraction strap
are down. See
“Identify the Data Cable” on page 66
.
8. Slowly move the connector in.
As you slide the connector in, the shell should be in the center of the QSFP
receptacle.
■
If the connector stops or binds after about 1/4 in. (5 mm) travel, back out and
repeat from
Step 7
.