Troubleshoot Hardware Faults
Troubleshooting and Diagnostics
41
For indicator blink rate information, see
“Indicator Blink Rates” on page 43
.
Memory Failure
For a server with a failure in the memory subsystem, the amber Service Action Required and
MEM TOP indicators are on steady. The green system OK indicator and the green SP indicator
are on steady.
For indicator blink rate information, see
“Indicator Blink Rates” on page 43
.
CPU Failure
For a server with a fault in the processor subsystem, the amber Service Action Required and
CPU TOP indicators are on steady. The activity of green system OK indicator and the green SP
indicator vary depending on whether the server can boot successfully. The server might not be
able to boot out of standby power mode.