Remove a Memory Riser Card
Servicing CRU Components
131
You must replicate this same DIMM population configuration on the replacement card.
The slots are color coded (for more information, see
).
Note -
Ensure that you replicate the same DIMM configuration on the replacement card.
5.
Transfer the DIMMs from the slots on the faulty MR card to the same slots on the
replacement card:
Tip -
Transfer the DIMMs from the faulty card to the replacement card one at a time.
a.
Remove a DIMM from the faulty MR card. See
.
b.
Install the DIMM on the replacement card. See
.
c.
Repeat the above steps until all DIMMs are transferred from the faulty card
to the replacement card.
6.
“Install a Memory Riser Card” on page 138
7.
Prepare the server for operation. See
.
Remove a Memory Riser Card
When servicing the components in this section, unplug the AC power cords and use ESD
protection.
Use this procedure to remove a memory riser (MR) card to:
■