Servicing the SP Card (FRU)
Servicing FRU Components
215
To ensure proper alignment of the Fault Remind switch, both tabs
must
be engaged with
their slots.
16.
Connect the power cable, ribbon data cable, and any SAS/SATA cables.
The mini-SAS plug that terminates the short SAS/SATA cable must be inserted into the upper
mini-SAS connector on the disk backplane. This short cable connects the SATA DVD to its
USB-SATA bridge on the motherboard. The longer SAS/SATA cable connects drive bays 4
and 5 to a storage device in the back of the system. The lower mini-SAS connector on the disk
backplane requires the standard, four-channel mini-SAS cable for drive bays 0 to 3.
17.
Install all disk drives and filler panels.
“Install a Storage Drive (CRU)” on page 111
18.
Install the DVD drive. See
“Install the DVD Drive or DVD Drive Filler
.
19.
Prepare the server for operation. See
.
Note -
The product serial number used for service entitlement and warranty coverage might
need to be reprogrammed by authorized service personnel with the correct product serial
number.
Servicing the SP Card (FRU)
The service processor (SP) card runs the embedded server management software, Oracle ILOM.
The motherboard-mounted SP card is replaceable. It is located inside at the back end of the
server between PCIe slots 6 and 7.
This section describes how to remove and replace the motherboard-mounted SP card.
■
“Remove the SP Card (FRU)” on page 215
■
“Install the SP Card (FRU)” on page 217
Remove the SP Card (FRU)
When servicing the components in this section, unplug the AC power cords and use ESD
protection.
Summary of Contents for Sun Server X4-4
Page 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Page 2: ......
Page 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Page 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Page 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Page 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Page 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Page 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Page 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Page 292: ...292 Sun Server X4 4 Service Manual October 2015 ...