Preparing for Installation
Oracle Exadata Storage Expansion Full
Rack
Oracle Exadata Storage Expansion Half
Rack
Oracle Exadata Storage Expansion Quarter
Rack
- 600 GB 15 K RPM High Performance
SAS disks or 3 TB 7.2 K RPM High
Capacity SAS disks (first Exadata
Storage Server type)
†
or
- 1.2 TB 10 K RPM High Performance
SAS disks or 4 TB 7.2 K RPM High
Capacity SAS disks (second Exadata
Storage Server type)
■ 3 Sun Datacenter InfiniBand Switch 36
■ High speed flash:
- 28.8 TB of raw flash capacity (first
Exadata Storage Server type)
‡
or
- 57.6 TB of raw flash capacity (second
Exadata Storage Server type)
‡
■ Keyboard, video, and mouse (KVM)
hardware
■ 2 redundant 15 kVA PDU (single-phase
or three-phase, high voltage or low
voltage)
■ 1 48-port Cisco Catalyst 4948, model
number WS-C4948-S Ethernet switch
- 600 GB 15 K RPM High Performance
SAS disks or 3 TB 7.2 K RPM High
Capacity SAS disks (first Exadata
Storage Server type)
†
or
- 1.2 TB 10 K RPM High Performance
SAS disks or 4 TB 7.2 K RPM High
Capacity SAS disks (second Exadata
Storage Server type)
■ 3 Sun Datacenter InfiniBand Switch 36
■ High speed flash:
- 14.4 TB of raw flash capacity (first
Exadata Storage Server type)
‡
or
- 28.8 TB of raw flash capacity (second
Exadata Storage Server type)
‡
■ Keyboard, video, and mouse (KVM)
hardware
■ 2 redundant 15 kVA PDUs (single-
phase or three-phase, high voltage or low
voltage)
■ 1 48-port Cisco Catalyst 4948, model
number WS-C4948-S Ethernet switch
- 600 GB 15 K RPM High Performance
SAS disks or 3 TB 7.2 K RPM High
Capacity SAS disks (first Exadata
Storage Server type)
†
or
- 1.2 TB 10 K RPM High Performance
SAS disks or 4 TB 7.2 K RPM High
Capacity SAS disks (second Exadata
Storage Server type)
■ 2 Sun Datacenter InfiniBand Switch 36
■ High speed flash:
- 6.4 TB of raw flash capacity (first
Exadata Storage Server type)
‡
or
- 12.8 TB of raw flash capacity (second
Exadata Storage Server type)
‡
■ Keyboard, video, and mouse (KVM)
hardware
■ 2 redundant 15 kVA PDUs (single-
phase or three-phase, high voltage or low
voltage)
■ 1 48-port Cisco Catalyst 4948, model
number WS-C4948-S Ethernet switch
†
In earlier releases, the high capacity disks were 2 TB.
‡
For raw capacity, 1 GB = 1 billion bytes. Capacity calculated using normal space terminology of 1 TB = 1024 * 1024 * 1024 * 1024 bytes. Actual formatted
capacity is less.
Preparing for Installation
These topics provide information to prepare your site for the installation of the Oracle Exadata
Storage Expansion Rack. Planning for the expansion rack is similar to planning for Oracle
SuperCluster T5-8. This section contains information specific to the expansion rack, and also
“Preparing the Site” on page 95
for general planning information.
■
“Reviewing System Specifications” on page 289
■
“Reviewing Power Requirements” on page 289
■
“Preparing for Cooling” on page 293
■
“Preparing the Unloading Route and Unpacking Area” on page 296
■
“Preparing the Network” on page 297
288
Oracle SuperCluster T5-8 Owner's Guide • May 2016
Summary of Contents for SuperCluster T5-8
Page 1: ...Oracle SuperCluster T5 8 Owner s Guide Part No E40167 17 May 2016 ...
Page 2: ......
Page 11: ...Contents Index 353 11 ...
Page 12: ...12 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 14: ...14 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 116: ...116 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 204: ...204 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 228: ...228 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 244: ...244 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...