Understanding the Software Configurations
■
Storage private network
: Connections through P1 (active) on the InfiniBand HCA
associated with the
first
CPU in the domain and P0 (standby) on the InfiniBand HCA
associated with the
second
CPU in the domain.
For example, for the first Medium Domain in a Full Rack, these connections would be
through P1 on the InfiniBand HCA installed in slot 3 (active) and P0 on the InfiniBand
HCA installed in slot 11 (standby).
■
Exadata private network
: Connections through P0 (active) and P1 (standby) on all
InfiniBand HCAs associated with the domain.
For example, for the first Medium Domain in a Full Rack, connections would be made
through both InfiniBand HCAs (slot 3 and slot 11), with P0 on each as the active
connection and P1 on each as the standby connection.
■
Application Domain:
■
Storage private network
: Connections through P1 (active) on the InfiniBand HCA
associated with the
first
CPU in the domain and P0 (standby) on the InfiniBand HCA
associated with the
second
CPU in the domain.
For example, for the first Medium Domain in a Full Rack, these connections would be
through P1 on the InfiniBand HCA installed in slot 3 (active) and P0 on the InfiniBand
HCA installed in slot 11 (standby).
■
Oracle Solaris Cluster private network
: Connections through P0 (active) on the
InfiniBand HCA associated with the
first
CPU in the domain and P1 (standby) on the
InfiniBand HCA associated with the
second
CPU in the domain.
For example, for first Medium Domain in a Full Rack, these connections would be
through P0 on the InfiniBand HCA installed in slot 3 (active) and P1 on the InfiniBand
HCA installed in slot 11 (standby).
Understanding Small Domains (Full Rack)
Note -
If you have the Full Rack, you cannot install a Fibre Channel PCIe card in a slot that
is associated with a Small Domain. In Full Rack configurations, Fibre Channel PCIe cards
can only be added to domains with more than one 10-GbE NIC. One 10-GbE NIC must be
left for connectivity to the client access network, but for domains with more than one 10-GbE
NICs, other 10-GbE NICs can be replaced with Fibre Channel HBAs. See
Full Rack Configurations” on page 69
for more information on the configurations with
“Using an Optional Fibre Channel PCIe Card” on page 139
for more
information on the Fibre Channel PCIe card.
These topics provide information on the Small Domain configuration for the Full Rack:
■
“Percentage of CPU and Memory Resource Allocation” on page 81
80
Oracle SuperCluster T5-8 Owner's Guide • May 2016
Summary of Contents for SuperCluster T5-8
Page 1: ...Oracle SuperCluster T5 8 Owner s Guide Part No E40167 17 May 2016 ...
Page 2: ......
Page 11: ...Contents Index 353 11 ...
Page 12: ...12 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 14: ...14 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 116: ...116 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 204: ...204 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 228: ...228 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...
Page 244: ...244 Oracle SuperCluster T5 8 Owner s Guide May 2016 ...