Installing the air conditioner
1
Move the unit with the hose attached to the window so that it is at least 50
cm from the walls or other objects (see Figure 9).
fig. 9
2
Attach the flat end of the clutch to the hot blow air hose into the oval
opening on the window sealing panel assembly (see Figures 10 and 11).
Note:
The flat end of the coupling on the hot blowing air hose must be
correctly fitted into the opening in the sealing assembly.
The hose must not be broken, it must not be bent at an angle of more than
45° and the heat from it must be properly and adequately drained into the
exterior.
fig. 10
fig. 11
Important Notice!
The blowing hose has a length of 280 mm to 1,500 mm, which is the length
determined on the basis of this air conditioning specification.
Do not use extended hoses or change the supplied hose to another, as this
may affect the function of this air conditioner.
The hot air outlet must be smooth and correct.
The air conditioning may overheat if the blow pipe is caught.