OPTICODEC
E
85
ISDN Error Messages
Error message
Possible causes
Checkpoint/
workaround
• INVALID CALL
REFERENCE VALUE
• IDENTIFIED CHANNEL
DOES NOT EXIST
• CALL IDENTITY IN USE
• INCOMPATIBLE
DESTINATION
• DEST. ADDRESS MISSING
INCOMPLETE
• INVALID TRANSIT
NETWORK SELECTION
• INVALID MESSAGE,
UNSPECIFIED
• MANDATORY ELEMENT
MISSING
• MESSAGE TYPE NOT
IMPLEMENTED
• ILLEGAL MESSAGE
• INFORM. ELEMENT NOT
IMPLEMENTED
• INVALID INFORMATION
ELEMENT
• MESSAGE INCOMPATIBLE
TO CALL STATE
• RECOVERY ON TIMER
EXPIRY
• PROTOCOL ERROR,
UNSPECIFIED
These error messages are
generally caused by an in-
correctly set ISDN protocol.
• Check the set ISDN
protocol and try
again.
• “ --- “
ONLY FOR US PROTOCOLS
The ISDN network did not
report any error. The OC
may possibly have termi-
nated the corresponding
B-channel itself or it was
terminated by the remote
device.
• Check the set ISDN
protocol and try
again.
• SPID REQUEST PENDING
The querying of the SPID
numbers for ISDN has not
yet been answered.
• Check the SPID
number and
connection.
• SPID FAILED
The SPID was rejected by
the ISDN.
• Check the SPID
number and con-
nection.
• ILLEGAL SPID
The SPID number entered is
too short.
• SPID MISSING
A US protocol was set,
but no SPID number was
entered.
• Enter the SPID and
try again.
Summary of Contents for opticodec 7200
Page 1: ...OPTICODEC Handbuch 7200 7400 PC Remote ...
Page 2: ......
Page 3: ...7200 7400 Software V4 25 2007 OPTICODEC PC REMOTE Software V1 24 2007 Manual ...
Page 89: ......