2-36
INSTALLATION
ORBAN MODEL 1101
sound card without audio processing. Additionally, because the
P
ROCESSOR
R
ETURN
input is available, a Direct Mixer can pass both processed and unproc-
essed audio to a given output. The “unprocessed audio” is most commonly
emergency alert tones or test tones.
Set the
A
NALOG
O
UTPUT
L
EVEL
C
ONTROL
to 0dB (maximum) to achieve correct level
calibration for a +4 dBu reference level.
•
When the Analog Output is set to D
IRECT
M
IXER
1
or
D
IRECT
M
IXER
2
, a
–20dBfs 1kHz sinewave file produces –20dB at the Analog Output Me-
ter and 0dB on an external meter with VU ballistics connected to
OPTIMOD-PC’s analog output. This assumes that the external meter is
calibrated so that 0 VU = +4 dBu.
•
When the A
NALOG
I
NPUT
control is set to 0dB (maximum) and the
A
NALOG
O
UTPUT
control is set to 0dB (maximum), the system is properly
calibrated and set to unity gain with 20dB of headroom.
•
When the A
NALOG
I
NPUT
R
EFERENCE
L
EVEL
is set to +4dBu, a +4dBu input
level produces a –20dBfs digital output signal at the D
IGITAL
or W
AVE
outputs, and a –20dBfs input signal from the D
IGITAL
or W
AVE
inputs
produces a +4dBu output level.
•
If you use a digital reference level higher than –20dBfs or an analog
reference level higher than +4dB, you will lose headroom if you wish
to retain unity gain. Because the analog input’s absolute clipping level
is +24 dBu (with the A
NALOG
I
NPUT
R
EFERENCE
L
EVEL
set to + 4 dBu), reduc-
ing the setting of OPTIMOD-PC’s A
NALOG
I
NPUT
control will not regain
the lost headroom. For example, a +8 dBu analog reference level can
provide no more than 16 dB of headroom. For this reason, elevated
reference levels are not recommended for use with OPTIMOD-PC un-
less you fully understand the headroom tradeoffs that result.
3.
Select the Stereo/Mono input mode for the analog input.
You can choose whether the fader operates on both stereo channels applied to
the analog input or if it operates in mono, driving the left and right channels of
the processing with identical signals. The choices are:
•
Stereo
•
Mono from the left-channel input
•
Mono from the right-channel input
•
Mono from the sum of the left and right channel inputs
Choose the functionality you want from the
S
TEREO
/M
ONO
drop-down list (found
on the I/O mixers below the corresponding faders). The default is
S
TEREO
.
4.
Adjust the Processor Mixer analog input fader.
This step adjusts the drive to OPTIMOD-PC’s audio processing so that it operates
in its preferred range.
Summary of Contents for Optimod-PC 1101
Page 4: ......
Page 14: ......
Page 121: ...OPTIMOD PC OPERATION 3 1 Section 3 Operation Figure 3 1 The OPTIMOD PC Control Application...
Page 192: ...3 72 OPERATION ORBAN MODEL 1101...
Page 204: ......
Page 210: ......
Page 212: ...5 2 UNINSTALLATION ORBAN MODEL 1101...
Page 236: ......